![EuroLite TMH-300 DMX User Manual Download Page 32](http://html1.mh-extra.com/html/eurolite/tmh-300-dmx/tmh-300-dmx_user-manual_2438398032.webp)
00049059.DOC, Version 1.0
32/38
Note:
After switching on, the device will automatically detect whether DMX 512 data is received or not. If the data
is received, the display will flash
"DMX"
. If there is no data received at the DMX-input, the display will not
flash
"DMX"
.
This situation can occur if:
- the XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap
in the input connector.
Note:
It’s necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order to
ensure proper transmission on the DMX data link.
DMX-protocol
Control-channel 1 - Horizontal movement (PAN) (within 540°)
Push slider up in order to move the head horizontally (PAN).
Gradual head adjustment from one end of the slider to the other (0-255, 128-center).
The head can be stopped at any position you wish.
Control-channel 2 - Vertical movement (TILT) (within 280°)
Push slider up in order to move the head vertically (TILT).
Gradual head adjustment from one end of the slider to the other (0-255, 128-center).
The head can be stopped at any position you wish.
Control-channel 3 - PAN/TILT-speed
Decimal Hexad. Percentage S/F
Feature
0 255
00 FF
0% 100%
F Decreasing speed
Control-channel 4 - Shutter, switching the lamp, reset
Decimal Hexad. Percentage S/F
Feature
0 143
00 8F
0% 56%
S No function
144 151
90 97
56% 59%
S Blackout at PAN/TILT-movement
152 159
98 9F
60% 62%
S Blackout at color change
160 167 A0 A7
63% 65%
S Blackout at gobo change
168 183 A8 B7
66% 72%
S No function
184 191 B8 BF
72% 75%
S Blackout at color/gobo-change
192 199 C0 C7
75% 78%
S Blackout at PAN/TILT-movement or color/gobo-change
200 207 C8 CF
78% 81%
S Lamp off (after approx. 3 sec.)
208 215 D0 D7
82% 84%
S Lamp on (after approx. 3 sec.)
216 239 D8 EF
85% 94%
S No function
240 247
F0 F7
94% 97%
S Reset (after approx. 5 sec.)
248 255
F8 FF
97% 100%
S No function