![EuroLite TMH-300 DMX User Manual Download Page 31](http://html1.mh-extra.com/html/eurolite/tmh-300-dmx/tmh-300-dmx_user-manual_2438398031.webp)
00049059.DOC, Version 1.0
31/38
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
CAUTION!
For security reasons the device starts operation not before installing the lamp!
Please follow the instructions in the chapter "Installing/Replacing the lamp"!
With the power switch, you can switch the device on and off.
After you connected the effect to the mains, the THM-300 starts running. During the Reset, the motors are
trimmed and the device is ready for use afterwards.
Stand Alone operation
In the Stand Alone mode, the THM-300 can be used without controller. Disconnect the THM-300 from the
controller and call the internal program.
Please refer to the instructions under Control Board.
DMX-controlled operation
You can control the projectors individually via your DMX-controller. Every DMX-channel has a different
occupation with different features. The individual channels and their features are listed under DMX-protocol.
Addressing
The Control Board allows you to assign the DMX starting address, which is defined as the first channel from
which the THM-300 will respond to the controller.
If you set, for example, the address to channel 15, the THM-300 will use the channel 15 to 28 for control.
Please, be sure that you don’t have any overlapping channels in order to control each THM-300 correctly
and independently from any other fixture on the DMX-chain.
If several THM-300 are addressed similarly, they will work synchronically.
Turn the encoder for setting the desired starting address. Now you can start operating the THM-300 via your