© EUROHEAT DISTRIBUTORS (H.B.S) LTD. July 2011
Instructions Part Number IN1232 Ed 1
14
Operating Mode Sub-Menu (see Menu Tree, Page 10)
It is possible to switch between boiler mode and heating stage/buffer mode in this menu.
Boiler Mode:
The appliance tries to reach and maintain a pre-defined set temperature (see Setup sub-menu). When or
shortly before this temperature is reached, the control system begins to reduce the output power, i.e. the boiler
modulates its output.
Heating Stage/Buffer Mode:
In heating stage/buffer mode, control system modulation is switched off and the boiler operates at a fixed,
pre-defined output stage. The boiler must, of course, be able to dissipate the output in question. Otherwise the
appliance overheats and goes into fault mode.
Setup Sub-Menu (see Menu Tree, Page 11)
Basic settings can be made in this menu.
Temperatures
Boiler set temperature: the temperature at which the control system operates in boiler mode.
Heating output: the output power used for heating in heating stage mode.
Buffer top On: with a buffer cylinder: the temperature at which the appliance switches on.
Buffer lower Off: with a buffer cylinder: the temperature at which the appliance switches off.
Date/Time
You can set the current time in this menu item.
Select language
Select your language for the menu.
Info Sub-Menu (see Menu Tree, Page 12)
You can obtain information about the appliance in this menu.
Appliance Info
This displays the status of the individual components at the current time.
Operating Info:
Provides information about the appliance operating mode and kilograms of pellets until the next service.
Software:
Shows the appliance software version installed.
Suction Conveying System Sub-Menu (see Menu Tree, Page 13)
Only if the suction conveying system is connected.
The various appliance filling times can be set via this menu.
If you only use a few pellets per day, it will not be necessary to set all four times.
You can also test the suction system via this menu.