Displays
This provides an overview of operating statuses and fault messages.
Operating Statuses:
The following displays provide information on the appliance’s current operating status. No action is required
on your part.
OFF
XXºC
Switched off by pressing the button.
Appliance does not restart automatically.
OFF-E
XXºC
Switched off via external requirement.
Appliance on standby and can be restarted via the external requirement.
OFF-B
XXºC
Switched off via buffer sensor.
Buffer full, appliance restarts automatically.
OFF-W
XXºC
Switched off due to overheating. After cooling down, appliance restarts automatically.
OFF-S
XXºC
Switched off by pellet suction conveying process. Appliance restarts automatically after suction
conveying process.
STOP
XXºC
Burnout phase
STOP-C
XXºC
Burnout phase, cooling phase
START
XXºC
Appliance starting up, ignition phase
H_43
XXºC
Heating-up phase (identified by “-“, appliance slowly moves up through the output stages
H_80
XXºC
Operating phase: displays the current output stage (for example 80%)
CL-MIN
Minor cleaning (after one hour)
CL-MAJ
Major cleaning (after five hours)
XX = curret boiler temperature