Euro Appliances EMJG30WSX Use And Care Manual Download Page 9

9

5) GAS CONNECTION

The gas connection is located in the rear and on
the right hand underside of these appliances:

90 mm

(

mod

:

EMJGC60SX

),

80 mm (mod:

EMJGC900SX

),

30 mm (mod: 

EMJG30WSX

).

There are two ways to carry out the connection to the
main gas line:

A. 

The hotplate can be connected with rigid pipe as

specified in AS/NZS 5601.

B. 

If  installing  with  a  hose  assembly,  install  with  a

hose  assembly  that  complies  with AS/ANZ  1869
(Australian  Certified),  10  mm  ID,  class  B  or  D,  no
more  than  1.2  m  long  and  in  accordance  with
AS/NZS  5601.  Ensure  that  the  hose  does  not
contact  the  hot  surfaces  of  the  hotplate,  oven,
dishwasher  or  any  other  appliance  that  may  be
installed  underneath  or  next  to  the  hotplate.  The
hose  should  not  be  subjected  to  abrasion,  kinking
or permanent deformation and should be able to be
inspected along its entire length with the hotplate in
the installed position.
Unions  compatible  with  the  hose  fittings  must  be
used and all connections tested for gas leaks.
The  gas  supply  connection  point  must  be
accessible with the appliance installed.

Natural Gas

Natural Gas installations require the connection of a
gas regulator at the appliance. 
Assemble  the  regulator  (noting  the  gas  flow
direction)  and  transition  piece,  in  accordance  with
figure 10.
The  transition  piece  on  the  supply  side  of  the
regulator must be provided by the installer.

Liquified Petroleum Gas

In  a  U-LPG  installation  the  gas  regulation  is  made
at  the  gas  cylinder  and  regulation  at  the  appliance
is  not  required. To  connect  supply  to  the  appliance
use 

transition 

pieces 

as 

shown 

in 

figure  11/A.  These  pieces  are  supplied  with  the
appliance on purchase.

WARNING:
THE  BURNER  FLAME  MUST  BE ADJUSTED  BY
THE INSTALLER.
FAULTY  INSTALLATION  WILL  NOT  BE
COVERED UNDER WARRANTY.
THE APPLIANCE IS FACTORY SET FOR NATURAL
GAS.  THE  TEST  POINT  PRESSURE  SHOULD  BE
ADJUSTED  TO  1.00kPa  WITH  THE  WOK  BURNER
OPERATING AT MAXIMUM.

INSTALLATION

FIG. 11

FIG. 11/A

Summary of Contents for EMJG30WSX

Page 1: ...EMJGC60SX EMJGC900SX EMJG30WSX COD 04041MS 07 07 2016 REV3...

Page 2: ...USE INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR BUILT IN HOTPLATE We ask that you carefully read the instructions within this booklet to enable you to abtain quality results from the outset The appl...

Page 3: ...b 8 Burner n 4 control knob 9 Burner n 2 control knob 10 Burner n 1 control knob 24 Double crown Wok burner 17 0 MJ 16 2 MJ 27 Burner n 24 control knob Attention this appliance has been manufactured f...

Page 4: ...ly be ignited when the relative knob has been set to the Full on position large flame fig 1 Matches can be used to ignite the burners in a blackout situation Never leave the appliance unattended when...

Page 5: ...opening a window or by increasing the power of the mechanical exhausting system if installed Do not attempt to change the technical characteristics of the product because it can be dangerous If you sh...

Page 6: ...n the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they...

Page 7: ...ce must be provided for the appliance 3 INSTALLING THE HOT PLATE Check that the appliance is in a good condition after having removed the outer packaging and internal wrappings from around the various...

Page 8: ...overlapping Evenly and securely fix the seal to the hot plate pressing into place with the fingers and remove the strip of protective paper from the seal and set the plate into the hole made in the ca...

Page 9: ...nstalled position Unions compatible with the hose fittings must be used and all connections tested for gas leaks The gas supply connection point must be accessible with the appliance installed Natural...

Page 10: ...10 FIG 12 FIG 13 B FIG 13 A FIG 13 FIG 12 a Side Control knob Frontal Control knob...

Page 11: ...appliance is connected to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 12 and 12 a taking care of r...

Page 12: ...checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type at one way Reduced rate adjustment Switch on...

Page 13: ...om panel near the gas connection 12 Fit the new data label included in the gas conversion kit 9 NATURAL GAS TO U LPG CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models EMJGC900S...

Page 14: ...regulating or pre regulating devices The envelope with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the...

Page 15: ...s given in paragraph 6 FIG 16 H05 RR F Section 3 X 0 75 mm2 Gas hot plate If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person i n...

Page 16: ...Centre whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare parts are only available from ou...

Reviews: