Euro Appliances EMJG30WSX Use And Care Manual Download Page 13

13

CONVERSIONS

8) UNIVERSAL-LP GAS TO NATURAL
GAS CONVERSION PROCEDURE

Appliance  models:  Gas  stainless  steel  hotplate
models:

EMJGC900SX

6 Burners

EMJGC60SX           4 Burners                    
EMJG30WSX

1 Burners

1.

Remove each burner cap and burner skirt.

2.

Remove  the  U-LPG  main  injector  with  a

7  mm/VF  tube  spanner  and  replace  with  the
appropriate size Natural Gas main injector for each
burner. The following injector sizes are required for
Natural Gas:

Burner

Main injector

Double crown, Item 1 on page 3

1.75 B mm

Rapid

1.55 B mm

Semi Rapid

1.16 B mm

Auxiliary

0.90 Bmm

Double crown, Item 24 on page 3

2 x123B+80 B mm

3.

Shut off gas supply to the appliance.

4.

Disconnect  gas  inlet  pipe  from  the  U-LPG  test

point inlet fitting.

5.

Remove  the  U-LPG    test  point  inlet  fitting  from

the appliance.

6.

Fit  the  Natural  Gas  Regulator  supplied  in  the

conversion kit.

7.

Connect the gas supply to the Regulator.

8.

Check for gas leaks. Do not use a naked flame

to check for gas leaks.

9.

Adjust the gas pressure to 1.00 kPa.

10.

Remove the control knob, with a thin shaft blade

screwdriver  down  the  centre  of  each  gas  valve
shaft,  screw  the  by-pass  injector  anti-clockwise.
Test  the  appliance  on  both  high  and  low  flame  for
each  burner.  If  the  burner  fails  to  remain  alight  or
the flame is not stable on the simmer setting, adjust
the by-pass screw, until flame is stable.

11.

If  not  already  removed,  remove  the  “Only  for

use  with  U-LPG  label  adhered  to  the  bottom  panel
near the gas connection.

12.

Fit  the  new  data  label  included  in  the  gas

conversion kit.

9) NATURAL GAS TO U-LPG
CONVERSION PROCEDURE

Appliance  models:  Gas  stainless  steel  hotplate
models:

EMJGC900SX

6 Burners

EMJGC60SX        4 Burners                    
EMJG30WSX

1 Burners

1. 

Remove each burner cap and burner skirt.

2.

Remove  the  Natural  Gas  main  injector  with  a

7  mm/VF  tube  spanner  and  replace  with  the
appropriate size U-LPG Gas main injector for each
burner. The following injector sizes are required for
U-LPG Gas:

Burner

Main injector

Double crown, Item 1 on page 3

1.00 B mm

Rapid

0.95 B mm

Semi Rapid

0.72 B mm

Auxiliary

0.56 B mm

Double crown, Item 24 on page 3 2 x123B+80 B mm

3. 

Remove the control knob, with a thin shaft blade

screwdriver  down  the  centre  of  each  gas  valve
shaft, screw the by-pass injector fully clockwise.

4.

Shut off gas supply to the appliance.

5.

Disconnect  gas  inlet  pipe  from  the  Natural  Gas

Regulator.

6.

Remove  the  Natural  Gas  Regulator  from  the

appliance.

7.

Fit the U-LPG Gas test point inlet fitting supplied

in the conversion kit.

8.

Connect the gas supply to the inlet fitting.

9.

Check for gas leaks. Do not use a naked flame

to check for gas leaks.

10.

Adjust the gas pressure to 2.75 kPa.

11.

Test  the  appliance  on  both  high  and  low  flame

for  each  burner  and  check  the  gas  pressure.  If  the
burner  fails  to  remain  alight  or  the  flame  is  not
stable  on  the  simmer  setting,  adjust  the  by-pass
screw until flame is stable.

12.

If  not  already  removed,  remove  the  “Only  for

use  with  Natural  Gas”  label  adhered  to  the  bottom
panel near the gas connection.

13.

Fit  the  new  data  label  included  in  the  gas

conversion kit.

Summary of Contents for EMJG30WSX

Page 1: ...EMJGC60SX EMJGC900SX EMJG30WSX COD 04041MS 07 07 2016 REV3...

Page 2: ...USE INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR BUILT IN HOTPLATE We ask that you carefully read the instructions within this booklet to enable you to abtain quality results from the outset The appl...

Page 3: ...b 8 Burner n 4 control knob 9 Burner n 2 control knob 10 Burner n 1 control knob 24 Double crown Wok burner 17 0 MJ 16 2 MJ 27 Burner n 24 control knob Attention this appliance has been manufactured f...

Page 4: ...ly be ignited when the relative knob has been set to the Full on position large flame fig 1 Matches can be used to ignite the burners in a blackout situation Never leave the appliance unattended when...

Page 5: ...opening a window or by increasing the power of the mechanical exhausting system if installed Do not attempt to change the technical characteristics of the product because it can be dangerous If you sh...

Page 6: ...n the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they...

Page 7: ...ce must be provided for the appliance 3 INSTALLING THE HOT PLATE Check that the appliance is in a good condition after having removed the outer packaging and internal wrappings from around the various...

Page 8: ...overlapping Evenly and securely fix the seal to the hot plate pressing into place with the fingers and remove the strip of protective paper from the seal and set the plate into the hole made in the ca...

Page 9: ...nstalled position Unions compatible with the hose fittings must be used and all connections tested for gas leaks The gas supply connection point must be accessible with the appliance installed Natural...

Page 10: ...10 FIG 12 FIG 13 B FIG 13 A FIG 13 FIG 12 a Side Control knob Frontal Control knob...

Page 11: ...appliance is connected to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 12 and 12 a taking care of r...

Page 12: ...checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type at one way Reduced rate adjustment Switch on...

Page 13: ...om panel near the gas connection 12 Fit the new data label included in the gas conversion kit 9 NATURAL GAS TO U LPG CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models EMJGC900S...

Page 14: ...regulating or pre regulating devices The envelope with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the...

Page 15: ...s given in paragraph 6 FIG 16 H05 RR F Section 3 X 0 75 mm2 Gas hot plate If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person i n...

Page 16: ...Centre whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare parts are only available from ou...

Reviews: