Eureka Vacuum System Cleaner Owner'S Manual Download Page 6

Cloth Filter

If the disposable paper bag is full or a filter is clogged, no air can pass through the unit and no cleaning will take place.
Remove and dispose of the paper bags.

NOTE: Disconnect power cord from electrical outlet before cleaning the filter.

NOTE: The cloth filter must remain in place even if the paper filter is used.

The elbow with the paper bag adapter must be installed, locked in its L slots, in the body facing downward as shown for the
paper bag.

1.

Remove the lower dirt recptacle.

2.

Wrap a large garbage bag around the lower portion of the power unit and hold firmly in position.

3.

Grasp the cloth filtr through the plastic bag and shake. Dirt will drop into bag.

4.

Carefully remove the plastic bag from the unit and discard.

5.

Replace the dirt receptacle on unit.

Replacement of the Cloth Filter Bag

NOTE: Removal of cloth filter is not advised and is not normally necessary.

The band in the rim of cloth filter must be secured into corresponding groove in Intermediate Body to
ensure an airtight seal.

If for any reason, the cloth filter has been dislodged during shipment it must be reinstalled prior to use.

Fold back filter band, align it with groove in body and uncoil. Final portion of band should require a slight
push to POP it into place. If not, remove and repeat installation procedure.

HOME MAINTENANCE GUIDE

If you experience trouble with your built-in vacuum system, follow the suggestions below before calling for service.

LOSS OF SUCTION POWER:

Be sure lid is on properly.

Empty dirt receptacle.

Clean filter.

Be sure each inlet valve is properly closed.

Check for hose obstruction.
Plug hose coupling into any inlet valve. Then, as you check each of the other inlet valves, raise the inlet cover and hold
your hand over the opening to check for suction. If there is normal suction at each inlet, then insert the hose into one
of the other inlets. If there is no suction through the hose at the second inlet, the blockage is in the hose. To clear the
hose obstruction, insert a blunt instrument into the hose (garden hose, wood dowel). If there is one inlet valve without
normal suction and you have checked for hose blockage, then the blockage is in the pipe system between the blocked
inlet valve and the power unit (see instructions below).

Clear blockage in pipes 
Insert the hose into the inlet valve where there is no suction; hold your hand over the hose end. Release hand quickly.
Repeat several times. If blockage does not clear, contact your nearest service station/dealer.

POWER UNIT WILL NOT START:

• Reset the overload protection device by following the directions on the Overload Protection Reset section of the manual.

NOTE: The safety device breaks the circuit of the motor is overloaded. 

• Check for blown fuse in main house supply box.
• Unplug the power unit from the electrical outlet and check all wall inlet and motor wiring connections for loose wires.

POWER UNIT WILL NOT STOP RUNNING:

• Check inside each inlet valve for obstruction of low voltage contacts. If no visual obstruction can be detected, discon-

nect the vacuum from the electrical outlet and contact your nearest service station/dealer.

6

Summary of Contents for Vacuum System Cleaner

Page 1: ...Invented for the way you clean TM Owner s manual Manuel du propri taire Manual del propietario Model No de mod le N de modelo Serial No de s rie N de serie...

Page 2: ...nnect to a properly grounded outlet only refer to Grounding Instructions Do not use extension cords or outlets with inadequate current carrying capacity Turn off all controls before unplugging Do not...

Page 3: ...ousehold dirt and dust Avoid picking up hard or sharp objects with the system to prevent hose and plastic pipe damage or clogs Service Information The instructions in this booklet serve as a guide to...

Page 4: ...th the unit on the wall align the power unit intake fitting with the main pipe projecting from the wall and connect these together DO NOT GLUE At this point the utility valve can be installed in the o...

Page 5: ...of machine usage When the last bar is flashing service is urgently required HOW TO MAINTAIN The instructions given in the booklet serve as a guide to routine maintenance Proper airflow or suction can...

Page 6: ...TION POWER Be sure lid is on properly Empty dirt receptacle Clean filter Be sure each inlet valve is properly closed Check for hose obstruction Plug hose coupling into any inlet valve Then as you chec...

Page 7: ...Station or for service information telephone toll free USA 1 800 282 2886 Further Limitations and Exclusions This is the sole and exclusive warranty of The Eureka Company Any warranty that may be impl...

Page 8: ...is covered for a period of one year 7 YEAR MOTOR AND ELECTRICAL GUARANTEE The electrical components and the motor of your Eureka central vacuum including the carbon brushes will be free from material...

Page 9: ...la section Instructions de mise la terre N utilisez pas de cordons de rallonge ou de prises dont l intensit de courant admissible est inad quate Mettez toutes les commandes de l appareil arr t avant d...

Page 10: ...durs ou pointus afin de ne pas bloquer ou endommager le boyau ou la tuyauterie en plastique Information concernant le service Les directives contenues dans ce manuel servent de guide pour l entretien...

Page 11: ...principale de tuyauterie et raccordez les NE COLLEZ PAS ce point la prise utilitaire peut tre install dans l autre raccord d admission non utilis Raccordez le tuyau d chappement ou silencieux s il y...

Page 12: ...u une v rification et un entretien appropri s soit faits afin d viter d avoir payer pour des frais d entretien ou de r paration majeurs Indicateur d heures de service L indicateur d heures de service...

Page 13: ...ettoyez le filtre Assurez vous que le couvercle de chaque prise d admission est bien ferm Assurez vous que rien n obstrue le boyau Branchez le boyau dans n importe quelle prise d admission Puis chacun...

Page 14: ...ion sont couverts pour une p riode d un an GARANTIE DE 7 ANS SUR LE MOTEUR ET LES COMPOSANTES LECTRIQUES Les composantes lactriques at le moteur de votre syst me central d aspiration Eureka incluant l...

Page 15: ...lo a un tomacorriente debidamente puesto a tierra consulte las instrucciones para la puesta a tierra No utilice cables de extensi n ni tomacorrientes con una capacidad de corriente incorrecta Apague t...

Page 16: ...pl stico Informaci n de servicio Las instrucciones que aparecen en este manual sirven como gu a para el mantenimiento de rutina Para m s informaci n p ngase en contacto con el centro de servicio de g...

Page 17: ...or Ubique los dos cables de bajo voltaje cerca de la tuber a principal y con ctelos al tablero de control de la unidad motriz utilizando los bornes provistos Aseg rese de cumplir con los c digos y reg...

Page 18: ...adecuado y una aspiraci n adecuada si el recept culo de polvo y el filtro se mantienen limpios y la tuber a de pl stico y la manguera se mantienen libres de obstrucciones Consulte la Gu a de mantenimi...

Page 19: ...nexi n de la manguera en cualquier v lvula de entrada Luego a medida que revise cada una de las otras v lvulas levante la tapa y ponga la mano sobre la abertura para comprobar la aspiraci n Si hay una...

Page 20: ...Part 460390 07 07...

Reviews: