EUM/OPS/MAN/13/730927
v3F e-signed, 15 April 2016
Ayecka SR1 DVB Receiver EUMETCast Setup Guide
Page 9 of 36
The zip files contain the binary
SRCFG.exe
and an ASCII file containing the default configuration
sr1cfg.cfg
(
Do not change the configuration file!
).
The SR1 local configuration and management interface uses Serial over USB; to use the Serial over USB you
must install the Virtual Com driver, on the Client PC;
after installing and configuring the Com driver and
connecting SR1 to your Client PC as indicated in the paragraph 3.1, wait until the Power LED is Green
(~15 seconds) then launch SR1CFG.exe!
SR1CFG will generate a log file “sr1cfg.log”; it can be used to check the applied configuration!
Notes:
It is required that the .Net framework is installed on the machine used to perform the configuration, the
.Net framework 3.5+ is part of the Win7 and later standard distributions, for XP (and win7 if not
installed) the latest .NET version can be downloaded and installed;
If more than one receiver are connected to the Client PC, SR1CFG will configure only the first one it
finds, so make sure only the receiver to be configured is connected via USB;
It is recommended to unplug the receiver from power then plug it back before launching SR1CFG.exe;
If the automatic configuration is taking too long (more than 5 minutes), stop SR1CFG unplug the
receiver from power, plug it back and run SR1CFG.exe again;
The applied configuration using SR1CFG.exe may sometimes differ from the expected configuration
due to communication issues;
To verify the results of that operation (or
manually configure the receiver
) you may also use putty (or
any other “Windows® HyperTerminal”) to connect to the receiver via the USB cable. For more details
regarding the expected configuration parameters and how to use
putty
see the sections
configure a putty
session to connect to the receiver
and
Manual receiver configuration
.
After this configuration, the applied configuration can be also checked by connecting to the management IP via
telnet (the configured management IP is
192.168.10.99
).
4.3
Management via Telnet
After connecting the LAN cable to management port (you can also connect it to the traffic port if the
management and traffic networks are “
Connected
” and the management multicast is
ON
, see the
network
configuration parameters
table for more details):
telnet 192.168.10.99
(user=telnet, password=telnet)
==================================================================
SR1c Serial No. 111700 30AAC Run Time: 46:11:04
Software Version 1.05b255 Hardware Version 2.00 Firmware Version 2.02b922
RX1: Active, Locked
EUMETCast DVB-S2 1512.500 MHz, DVB-S2 16APSK 2/3, 32.996 Msps, ACM, 13.4 dB
RX2: Not Active, Not Locked
ile 2 1100.000 MHz, Auto
==================================================================
1. Configuration
2. Status
3. Network
4. System
5. Statistics
6. ACM Client