Ayecka SR1 DVB Receiver EUMETCast Setup Guide
Page 11 of 36
================================================================================
SR1c Serial No. 111700 30AAC Run Time: 101:49:11
Software Version 1.05b255 Hardware Version 2.00 Firmware Version 2.02b922
RX1: Active, Locked
EUMETCast DVB-S2 1512.500 MHz, DVB-S2 16APSK 2/3, 32.993 Msps, ACM, 12.0 dB
RX2: Not Active, Not Locked
Profile 1 1100.000 MHz, Auto
================================================================================
1. Configuration
2. Status
3. Network
4. System
5. Statistics
6. ACM Client
N-B: To move to the previous menu enter “
0” (Zero)
4.5
Manual Receiver Configuration
4.5.1
Network Configuration
To configure the network Select
option 3
from the main menu
To set a fixed IP for management the management DHCP Client must be set to off:
Toggle with option 8
The network configuration parameters are shown as follow (see table below):
Network
=======
1. Management IP Address
192.168.10.99
2. Management IP Mask
255.255.255.0
3. Management Ethernet Address CC-F6-7A-04-CA-BA
4. Management IP Multicast
off
5. Management DSCP 0
6. Management VLAN ID 0
7. Management Default Gateway 0.0.0.0
8. Management DHCP Client
Off
(set to off to configure a fixed IP, options 1, 2)
9. Management Port State Enabled
A. LAN IP Address
192.168.10.102
(The data IP, Tellicast is running on a server on
the same network, 192.168.10.103)
B. LAN IP Mask 255.255.255.0
C. LAN Ethernet Address CC-F6-7A-04-CA-B9
D. LAN IP Multicast
On
E. Router IP Address 192.168.10.101
F. LAN DHCP Client Off
G. ARP Management
H. Air IP Address 192.168.1.161
I. Air Ethernet Address CC-F6-7A-04-CA-B8
J. Isolate Networks Isolated
N-B: at this point you can configure the management network which allows you to access the device via telnet
or SNMP