Operating Instructions

Enabling Switch ZXE

Correct use

The enabling switches described are manually 

actuated command switches that make it possi‑

ble to work in the danger zone of machines and 

installations. 
Enabling switches represent part of a safety‑related 

control system according to EN  ISO  13849‑1 or 

EN 62061 and fulfill a safety function. In conjunction 

with other safety functions, e.g. 

SLS = Safely Limited 

Speed according to EN  61800‑5‑2

, the enabling 

switches can be used as part of an enabling system 

according to EN ISO 12100 for working with open 

guards or switched‑off safety guards. The various 

safety guards must be activated via a control or 

operating mode selector that can be locked in every 

position or via an equivalent device.
The device possesses a three‑position enabling 

switch according to EN 60947‑5‑8 or is a device 

for enabling control with three positions according 

to EN  60204‑1. A dangerous movement is only 

allowed to be enabled in position 2 (center position). 

Authorized operating personnel can then enter the 

danger zone, e.g.:

 

f

for setting up

 

f

for observing work sequences

 

f

for maintenance.

Before the device is used, a risk assessment must 

be performed on the machine, e.g. in accordance 

with the following standards:

 

f

EN ISO 13849‑1

 

f

EN ISO 12100

 

f

IEC 62061

Correct use includes observing the relevant require‑

ments for installation and operation, particularly 

based on the following standards:

 

f

EN ISO 13849‑1

 

f

EN 60204‑1

 

f

IEC 62061

Important!

 

f

The user is responsible for the integration of the 

device in a safe overall system. For this purpose, 

the overall system must be validated, e.g. in 

accordance with EN ISO 13849‑2.

 

f

The enabling switch user must assess and 

document remaining risks.

 

f

If a data sheet is included with the product, the 

information on the data sheet applies.

Description of the safety function

If dual‑channel evaluation of the enabling switch 

is used with monitoring for same contact state 

or antivalent contact state, category 3 as per 

EN ISO 13849‑1 is achieved.
Devices from this series feature the following safety 

function:

Enable control  

(manually activated interlocking function in a 

control system according to EN 60204‑1)

Safety function:

 

f

If the enabling switch is not pressed (position 1), 

at least one of the contacts is open.

 

f

If the enabling switch is pressed all the way down 

(position 3), at least one of the contacts is open.

Safety characteristic: 

 

f

B

10D

 (see section 

Technical data

).

Exclusion of liability and warranty

In case of failure to comply with the conditions for 

correct use stated above, or if the safety regula‑

tions are not followed, or if any servicing is not 

performed as required, liability will be excluded and 

the warranty void.

General safety precautions

Enabling switches fulfill personnel protection func‑

tions. Incorrect installation or tampering can lead to 

fatal injuries to personnel.
Check the safe function of the guard particularly

 

f

after any setup work

 

f

after the replacement of a system component

 

f

after an extended period without use

 

f

after every fault.

Independent of these checks, the safe function of 

the guard should be checked at suitable intervals 

as part of the maintenance schedule.

 

f

No commands for potentially hazardous conditions 

are allowed to be initiated with enabling switches 

alone.

 

f

The safety function of enabling switches must not 

be bypassed (bridging of contacts), tampered with 

or otherwise rendered ineffective.

 

f

The enabling switch must be protected against 

tampering by the operator.

 

f

Enabling switches may be used only by autho‑

rized persons who can recognize hazards in 

time and who are able to take appropriate action 

immediately.

 

f

Every person present in the danger zone must car‑

ry his/her own enabling switch on his/her person.

 

f

Mounting, electrical connection and setup only by 

authorized personnel.

In the event of malfunctions or damage, the en‑

abling switch must be replaced. The device may be 

repaired only by the manufacturer.

Important!

Prior to use, read the operating instructions and 

keep these in a safe place. Ensure the operating 

instructions are always available during mount‑

ing, setup and servicing. You should archive a 

printed copy of the operating instructions. You 

can download the operating instructions from 

www.euchner.com.

Function

Enabling switches are used as a manual interlocking 

device for a control system (enable control). In posi‑

tion 2, the enabling switch permits machine opera‑

tion with a separate start control. In position 1 and 

in position 3, a stop function must be initiated by the 

machine control and machine operation prevented.

 

f

Position 1:   Off function, pushbutton not pressed

 

f

Position 2:  Enabling function (ON), pushbutton 

pressed to center position (actuating 

point)

 

f

Position 3:  Off function, pushbutton pressed to 

end stop

The enabling function is canceled by releasing the 

pushbutton or pressing it beyond the actuating 

point. The enabling function does not reactivate as 

it passes position 2 while returning from position 3 

to position 1.
With versions ZXE‑104833, ZXE‑111276 and 

ZXE‑120348, a click sounds during the change from 

position 1 to position 2 and during the return from 

position 2 to position 1.

Mounting

Important!

The enabling switch must be fitted in a suitable 

housing.

 

f

Screw the knurled nut on the enabling switch 

down as far as possible and slide enabling switch 

without protective cap through the front panel 

cut‑out from the rear.

 

f

Screw protective cap onto the front of the enabling 

switch to the end stop.

 

f

Screw the knurled nut against the control panel 

and tighten.

 

f

During installation it must be ensured that all three 

switch positions can be reached unhindered.

 

f

The control element must be securely fastened, 

but must not be placed under stress by the 

fastening.

 

f

The device must be installed so that tampering 

is not possible by simple mechanical measures 

(clamping, adhesive tape, etc.).

Electrical connection

 WARNING

There will be no safety function if installed or 

connected incorrectly. This situation can result 

in serious accidents and injuries or even fatality.

 

f

Installation and electrical connection must be 

performed only by qualified personnel.

 

f

All electrical outputs must have an adequate 

protective circuit for inductive loads. The outputs 

must be protected with a free‑wheeling diode for 

this purpose. RC interference suppression units 

must not be used.

Connecting enabling switch

Selecting contacts or contact combinations

Always use a dual‑channel, safe input to connect an 

enabling switch to a safety evaluation unit. Use the 

recommended contact combination (for example, 

see Figure 2).
If you use your own contact combination, please pay 

attention to the following notes:
Connect the enabling switch such that

 

f

Two independent switching contacts or contact 

combinations are used.

 

f

The switching contacts or contact combinations 

are either antivalent (one normally open contact 

and one normally closed contact) or equivalent 

(two normally closed contacts).

The parameters for this connection must be config‑

ured in the safe evaluation unit to suit the switching 

contacts chosen and their wiring. For this purpose 

use the appropriate parameters:

 

f

Dual‑channel equivalent evaluation
Both contacts are closed at the same time in the 

enabling position (position 2)

 

f

Dual‑channel antivalent evaluation
One contact is open in the enabling position (po‑

sition 2), the second closed

 

f

Discrepancy time
Activate the discrepancy monitoring. Because the 

two contacts never switch exactly simultaneously, 

you must specify a time within which simultaneity 

applies. A time of 3 s has proven appropriate for 

electromechanical contacts.

 

f

Resetting after fault detection
Select the parameter such that after a fault the 

enabling switch is automatically reset if both 

contacts were in the open position (for equivalent 

contacts) or one contact was open and the other 

closed (for antivalent contacts) and they are then 

placed again in the correct position for enabling. 

Summary of Contents for ZXE

Page 1: ...ktionsst rungen oder Besch digung muss der Zustimmtaster ausgetauscht werden Die Instand setzung des Ger ts darf nur durch den Hersteller erfolgen Wichtig Lesen Sie vor Gebrauch die Betriebsanleitung...

Page 2: ...in regelm igen Abst nden und nach jedem Fehler die korrekte Funktion des Ger ts Um eine einwandfreie und dauerhafte Funktion zu gew hrleisten sind folgende Kontrollen erforderlich f einwandfreie Scha...

Page 3: ...ZXE 120348 ZXE 091336 ZXE 104833 ZXE 111276 ZXE 120348 Druckpunkt S21 S11 S12 S10 S13 13 14 23 24 E1 E2 C1 C2 S14 Sicherheitsmodul ESM BA201 Zustimmtaster Start Ausg nge Freigabe Einrichtebetrieb Bild...

Page 4: ...the en abling switch must be replaced The device may be repaired only by the manufacturer Important Prior to use read the operating instructions and keep these in a safe place Ensure the operating ins...

Page 5: ...to ensure trouble free long term operation f correct switching function f damage heavy contamination dirt and wear f sealing of cable entry f loose cable connections or plug connectors Information Th...

Page 6: ...ts closed ZXE 091336 ZXE 104833 ZXE 111276 ZXE 120348 ZXE 091336 ZXE 104833 ZXE 111276 ZXE 120348 Actuating point S21 S11 S12 S10 S13 13 14 23 24 E1 E2 C1 C2 S14 Safety module ESM BA201 Enabling switc...

Page 7: ...gir imm diatement en cons quence f Chaque personne se tenant dans la zone de danger doit se munir de sa propre commande d assentiment f Montage raccordement lectrique et mise en service exclusivement...

Page 8: ...dommagement ou d usure il est n cessaire de remplacer enti rement l appareil Le remplacement de composants ou de sous en sembles n est pas autoris Toute r paration doit tre effectu e par le fabricant...

Page 9: ...11276 ZXE 120348 ZXE 091336 ZXE 104833 ZXE 111276 ZXE 120348 Point de d clenchement S21 S11 S12 S10 S13 13 14 23 24 E1 E2 C1 C2 S14 Module de s curit ESM BA201 Commande d assentiment D marrage Sorties...

Page 10: ...tallazione il collegamento elettrico e la messa in servizio sono da affidare esclusivamente al personale specializzato e autorizzato Sostituire il pulsante di consenso in caso di anomalie di funzionam...

Page 11: ...sostituire il dispositivo completo Non ammessa la sostituzione di singoli componenti o di gruppi Il dispositivo pu essere riparato solo dal fabbricante f Verificare il corretto funzionamento del disp...

Page 12: ...36 ZXE 104833 ZXE 111276 ZXE 120348 ZXE 091336 ZXE 104833 ZXE 111276 ZXE 120348 Punto di resistenza S21 S11 S12 S10 S13 13 14 23 24 E1 E2 C1 C2 S14 Modulo di sicurezza ESM BA201 Pulsanti di consenso A...

Reviews: