Operating Instructions
Safety System MGBS-P-L.-AP…
26
(translation of the original operating instructions) 2527245-02-01/22
11.11. Connection of guard locking control
11.11.1. Guard locking control for variants with IMM connection
Guard locking solenoid operating voltage,
24 V DC
IMP
IMM
Guard locking solenoid operating voltage,
0 V DC
Fig. 6:
Connection example with IMM connection
11.11.2. Guard locking control for variants without IMM connection
Guard locking solenoid operating voltage,
24 V DC
IMP
0 V
Electronics operating voltage and guard locking
solenoid operating voltage, 0 V DC
Fig. 7:
Connection example without IMM connection