51
2500233-04-10/21 (translation of the original operating instructions)
Operating Instructions Safety Systems
MGB2-L1…-BR.-… / MGB2-L2…-BR.-… and MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
EN
Reliability values acc. to EN ISO 13849-1
Guard lock monitoring
Control of guard locking
Category
4
4
Performance Level
PL e
PL e
MTTF
D 2)
750
750
years
Diagnostic Coverage DC
99
–
%
PFH
D
2.95 x 10
-9
2.95 x 10
-9
Mission time
20
20
years
Safety Integrity Level
SIL 3
SIL 3
Mechanical life
1 x 10
6
- In case of use as door stop, and 1 Joule impact
energy
0.1 x 10
6
B
10D
(emergency stop)
0.13 x 10
6
Emergency stop
Operating voltage
5 … 30
V
Operating current
1 … 100
mA
Breaking capacity, max.
250
mW
Power supply LED
24
V DC
Controls and indicators
Operating voltage
UB
V
Operating current
1 … 10
mA
Breaking capacity, max.
250
mW
Power supply LED
24
V DC
1) Values at a switching current of 50 mA without taking into account the cable length.
2) Fixed failure rate without consideration of faults in wearing parts.
16.1. Radio frequency approvals
Product description: Safety Switch
FCC ID:
2AJ58-03
IC: 22052-03
FCC/IC-Requirements
This device complies with part 15 of the FCC Rules and with Industry Canada’s licence-exempt RSSs. Operation is subject
to the following two conditions:
1) This device may not cause harmful interference, and
2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority
to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required
to correct the interference at his own expense.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploita-
tion est autorisée aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en