25
2500233-04-10/21 (translation of the original operating instructions)
Operating Instructions Safety Systems
MGB2-L1…-BR.-… / MGB2-L2…-BR.-… and MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
EN
9.3.2. Fitting and removing lenses and labels for controls and indicators
1
2
2
3
90°
Click!
1
Fitting
Removing
Lens
9.4. Changing direction of connection
CAUTION
Risk of damage to equipment or malfunction as a result of uncontrolled machine stop.
Ì
The direction of connection can be changed by removing the covers and mounting rotated by
180°.
Ì
The communication within the system is interrupted if the internal wiring is changed. If a process is
running, this situation can result in an uncontrolled stop and damage to the installation or the prod-
uct. Before replacement, make sure the installation is in a suitable operating status.
Fig. 12: Changing direction of connection