13.11. Terminal assignment, submodule with plug connector M23 (X7)
NOTICE
The following table applies to the submodule MSM-C-K-BA-SH0-S1-160849.
Various assembly options are possible. Refer to the data sheet of the submodule for the correct wiring
for your device.
12
1
2
3
4
5
6
7
8
9
10
11
18
13
14
15
16
17
19
Coding
(leading)
Fig. 28: View of connection side, plug connector M23 (X7)
Pin
Terminal
Designation
Description
1
X3.1
IMP
Guard locking solenoid operating voltage, 24 V DC
2
X1.2
FI1A
Enable input for channel A
If operated separately (BP), set DIP switch as per operating instructions.
3
X1.3
FI1B
Enable input for channel B
If operated separately (BP), set DIP switch as per operating instructions.
4
X1.8
FO1A
Safety output, channel A
ON when the door is closed and locked/interlocked.
Attention: Pay attention to the DIP switch position.
5
X2.8
FO1B
Safety output, channel B
ON when the door is closed and locked/interlocked.
Attention: Pay attention to the DIP switch position.
6
X1.1
UB
BR electronics operating voltage, 24 V DC
7
X2.7
RST
Reset input, device is reset if 24 V DC is applied to RST for min. 3 s.
8
X1.4
OT/C
Bolt tongue monitoring output
ON when the door is closed and the bolt tongue is inserted into the locking module.
Optional: BR diagnostic output
9
X1.7
OI
Monitoring output DIA
ON when the device is in the fault state.
10
X3.3
See the enclosed data sheet for the submodule
11
X3.5
12
–
n.c.
Not used
13
X3.4
See the enclosed data sheet for the submodule
14
X3.6
15
X2.2
16
X2.5
17
X3.7
18
X2.6
19
X2.1
0 V UB
BR electronics operating voltage, 0 V
X3.2
IMM
Guard locking solenoid operating voltage, 0 V
Table 3: Terminal assignment and contact description