3. Description of the safety function
Devices from this series feature the following safety functions:
The following applies to MGB-L1 and MGB-L2:
Monitoring of guard locking and the position of the guard
(interlocking device with guard locking according to EN ISO 14119)
Ì
-When guard locking is released, safety bit
FI.UK
(ÜK) = 0 (monitoring of the locking element).
-When the guard is open, safety bit
FI.SK
(SK) = 0.
-Guard locking can be activated only when the bolt tongue is located in the locking module (prevention of inadvertent
locking position (faulty closure protection)).
Ì
Safety characteristics: category, Performance Level, PFH
D
(see chapter
).
Control of guard locking (safety bit
FO.L
)
Ì
Safety function
If the device is used as guard locking for personnel protection, control of guard locking must be regarded as a safety
function. Guard locking is controlled via safety bit
FO.L
(see chapter
6.3. Guard locking for version MGB-L1 on page
.
The safety level of guard locking control is determined by the device PFHD
int.
and by the external control (e.g. PFHD
ext.
of
the standstill monitor).
PFHD
ext.
PFHD
int.
(internal electronic)
Guardlocking Device
MGB-EI
(e.g. standstill
monitor)
Safetybit
FO.L
(Guardlocking)
Ì
Safety characteristics: category, Performance Level, PFH
D
(see chapter
).
The following applies to MGB-L0:
Monitoring of the guard position
(interlocking device according to EN ISO 14119)
Ì
Safety function: When the guard is open, safety bit
FI.SK
(SK) = 0. (See chapter
.)
Ì
Safety characteristics: category, Performance Level, PFH
D