17
2126330-10-03/21 (translation of the original operating instructions)
Operating Instructions Safety Systems
MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A
EN
9. Mounting
WARNING
Mounting must be performed only by authorized personnel.
NOTICE
Risk of damage to equipment and malfunctions as a result of incorrect installation.
Ì
Observe EN ISO 14119:2013, sections 5.2 and 5.3, for information about mounting the safety
switch and the actuator.
With two-leaf hinged doors, one of the two door leaves must also be latched mechanically.
Use a rod latch (Item) or a double-door lock (Bosch Rexroth) for this purpose, for example.
Important!
Ì
In case of flush installation, the operating distances change as a function of the installation depth
and the guard material.
Locking
module
Handle module
Locking
module
Handle module
Surface mounting
Flush installation
Actuating range
Actuating range
Tip!
Ì
You can find various animations about the assembly process in the media library at
www.euchner.com.
Ì
The color and labeling of pushbuttons and indicators can be modified.
For mounting steps, see
Attach system such that operation of the auxiliary release as well as inspection and service are possible.
The locking screw of the auxiliary release must be returned to its original position and sealed before putting into operation
(with sealing lacquer, for example).