![EUCHNER CET.-AR Series Operating Instructions Manual Download Page 28](http://html.mh-extra.com/html/euchner/cet-ar-series/cet-ar-series_operating-instructions-manual_2434843028.webp)
Operating Instructions
Transponder-Coded Safety Switch CET.-AR-…
28
(Translation of the original operating instructions) 2110788-13-03/20
Monitoring
Output
Safety Inputs
Read Head
Actuator
GN
RD
Safety Outputs
Connected load
LED1
X2:2
LED2
X2:3
-B1
UB
X1:2
UCM
X2:4
X2:1
0V(UCM)
RST
X1:8
X1:7
0V(UB)
J
X2:5
X1:5
OUT
X1:3
OA
X1:4
OB
IA
X1:6
IB
X1:1
1
2
-F2
1
2
-F1
13
14
-S1
12
11
14
-S2
24V DC
0 V
24V DC
0 V
CET
Figure 4:
Wiring diagram A, CET 1/2-AR with plug connectors 2 x M12
Single-channel control of the guard locking solenoid
0 V
Monitoring
Output
Safety Inputs
Read Head
Actuator
GN
RD
Safety Outputs
4/8 F-DI
Digital
Output
PWR
Supply of
the control
4F-DO
LED1
X2:2
LED2
X2:3
-B1
UB
X1:2
UCM
X2:4
X2:1
0V(UCM)
RST
X1:8
X1:7
0V(UB)
J
X2:5
X1:5
OUT
X1:3
OA
X1:4
OB
IA
X1:6
IB
X1:1
-X1
DI4
DI0
DO
DC24V
M
-X1
DO..P
DO..M
1
2
-F1
1
2
-F2
24V DC
0 V
24V DC
CET
Figure 5:
Wiring diagram A, CET 1/2-AR with plug connectors 2 x M12
Dual-channel control of the guard locking solenoid