![EUCHNER CET.-AR Series Operating Instructions Manual Download Page 23](http://html.mh-extra.com/html/euchner/cet-ar-series/cet-ar-series_operating-instructions-manual_2434843023.webp)
23
2110788-13-03/20 (Translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CET.-AR-…
EN
10.6. Connector assignment for safety switch CET-AR with plug connectors 2 x M12
10.6.1. Version without door monitoring output (CET1/2)
Wiring diagram A
Plug connector
(view of connection side)
Pin
Designation
Function
Conductor coloring
of connecting ca-
ble
1)
2 x M12
X2.5
X1.8
X1.5
X1.6
X1.7
X1.2
X2.4
X2.3
X2.1
X2.2
X1.4
X1.3
X1.1
X 1.1
IB
Enable input for channel B
WH
X 1.2
U
B
Operating voltage of AR electronics, 24 V DC
BN
X 1.3
OA
Safety output channel A
GN
X 1.4
OB
Safety output channel B
YE
X 1.5
OUT
Monitoring output
GY
X 1.6
IA
Enable input for channel A
PK
X 1.7
0 V U
B
Operating voltage of AR electronics, 0 V
BU
X 1.8
RST
Reset input
RD
X 2.1
0 V U
CM
Operating voltage of guard locking solenoid, 0 V
BN
X 2.2
LED 1
LED 1 red, freely configurable, 24 V DC
WH
LED 1 red, solenoid energized
3)
X 2.3
LED 2
LED 2 green, freely configurable, 24 V DC
BU
X 2.4
U
CM
Operating voltage of guard locking solenoid, 24 V DC
BK
X 2.5
J
Version with teach-in input:
To teach-in a new actuator, connect to 24 V DC; leave open in normal
operation.
2)
GY
Y
Version with feedback loop:
If the feedback loop is not used, connect to 24 V DC.
FE
Function earth
Version without feedback loop and without teach-in input:
This connection must be connected to 0 V.
3)
-
Version without feedback loop and without teach-in input:
This connection must be connected to 0 V.
1) Only for standard EUCHNER connecting cable.
2) With dual-channel solenoid control, do not connect to 0 V U
B
.
3) Only for ID no. 109015
10.6.2. Version with door monitoring output (CET3/4)
Wiring diagram B
Plug connector
(view of connection side)
Pin
Designation
Function
Conductor coloring
of connecting ca-
ble
1)
2 x M12
X2.5
X1.8
X1.5
X1.6
X1.7
X1.2
X2.4
X2.3
X2.1
X2.2
X1.4
X1.3
X1.1
X 1.1
IB
Enable input for channel B
WH
X 1.2
U
B
Operating voltage of AR electronics, 24 V DC
BN
X 1.3
OA
Safety output channel A
GN
X 1.4
OB
Safety output channel B
YE
X 1.5
OUT
Monitoring output
GY
X 1.6
IA
Enable input for channel A
PK
X 1.7
0 V U
B
Operating voltage of AR electronics, 0 V
BU
X 1.8
RST
Reset input
RD
X 2.1
0 V U
CM
Operating voltage of guard locking solenoid, 0 V
BN
X 2.2
OUT D
Door monitoring output (indication on LED 2)
WH
X 2.3
LED 1
LED 1 red, freely configurable, 24 V DC
BU
X 2.4
U
CM
Operating voltage of guard locking solenoid, 24 V DC
BK
X 2.5
J
Version with teach-in input:
To teach-in a new actuator, connect to 24 V DC; leave open in normal
operation.
2)
GY
Y
Version with feedback loop:
If the feedback loop is not used, connect to 24 V DC.
FE
Function earth
Version without feedback loop and without teach-in input:
This connection must be connected to 0 V.
-
Version without feedback loop and without teach-in input:
This connection must be connected to 0 V.
1) Only for standard EUCHNER connecting cable.
2) With dual-channel solenoid control, do not connect to 0 V U
B