2105267-10-08/20 (Translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-AH-C03-AE-LS
EN
Reliability values acc. to EN ISO 13849-1
Category
3
Performance Level (PL)
d
PFH
D
1.03 x 10
-7
/ h
Mission time
20
years
1) Values at a switching current of 4 A without taking into account the cable lengths.
2) After the operating voltage is switched on, the semiconductor outputs are switched off during the ready delay.
3) The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure reliable detection of internal faults in the evaluation unit (self-monitoring).