![EUCHNER CES-AH-C03-AE-LS Operating Instructions Manual Download Page 16](http://html.mh-extra.com/html/euchner/ces-ah-c03-ae-ls/ces-ah-c03-ae-ls_operating-instructions-manual_2434825016.webp)
Operating Instructions
Non-Contact Safety Switch CES-AH-C03-AE-LS
16
(Translation of the original operating instructions) 2105267-10-08/20
11. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
11.1. Technical data for safety switch CES-AH-C03-AE-LS
Parameter
Value
Unit
min.
typ.
max.
Housing material
PBT plastic
Dimensions
40 x 40 x 168
mm
Weight
0.45
kg
Ambient temperature at U
B
= DC 24 V
-25
-
+70
°C
Storage temperature
-25
-
+70
Degree of protection
IP65/IP67
Safety class
III
Degree of contamination
3
Installation orientation
Any
Connection
Connecting cable PUR 0.5 m with connectors AMP Superseal
1 x 3-pin / 1 x 4-pin
Operating voltage U
B
(reverse polarity protected, regulated,
residual ripple < 5%)
9
-
32
V DC
Current consumption
-
-
150
mA
External fuse
(operating voltage, +LA and +LB)
0.25
-
10
A
Power supply for load U(+LA)/U(+LB)
U
B
Power supply for load via PWM
- Pulse frequency
-
-
1
kHz
- Mark/space ratio T
on
10
-
100
%
Safety outputs LA/LB
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U(LA)/U(LB)
1)
HIGH
U(LA)
U
B
-1.5
-
U
B
V DC
HIGH
U(LB)
LOW
U(LA)/U(LB)
0
4
Testing of the outputs
Test pulse length
- Test interval
-
10
-
-
6
-
ms
s
Switching current per safety output
30
-
4,000
mA
Utilization category acc. to EN 60947-5-2
DC-13 24 V 4 A
Caution: Outputs must be protected by a free-wheeling diode in the case of inductive loads.
Start input START
HIGH
8
-
U
B
V DC
LOW
0
-
2
Rated insulation voltage U
i
-
-
75
V
Rated impulse withstand voltage U
imp
-
-
1.5
kV
Rated conditional short-circuit current
-
-
100
A
Resilience to vibration
Acc. to EN 60947-5-2
Risk time
-
-
250
ms
Difference time between the two safety outputs
-
-
50
ms
Ready delay
2)
-
-
3
s
Dwell time
3)
0.5
-
-
s
Switching frequency
-
-
1
Hz
Repeat accuracy R acc. to EN IEC 60947-5-3
≤
10
%
Mounting distance between 2 switches or 2 actuators
80
-
-
mm
LED displays
2