![EUCHNER 106300 Operating Instructions Manual Download Page 18](http://html.mh-extra.com/html/euchner/106300/106300_operating-instructions-manual_2434808018.webp)
Operating Instructions
Non-Contact Safety Switch CES-AH-C03-AH-SM
18
(Translation of the original operating instructions) 106595-09-06/20
11. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
11.1. Technical data for safety switch CES-AH-C03-AH-SM
Parameter
Value
Unit
min.
typ.
max.
Housing material
PBT plastic
Dimensions
40 x 40 x 171
mm
Weight
0.35
kg
Ambient temperature at I(LA)/I(LB) > 3 A
-20
-
+55
°C
Ambient temperature at I(LA)/I(LB) < 3 A
-20
-
+70
Storage temperature
-25
-
+70
Degree of protection
IP67
Safety class
III
Degree of contamination
3
Installation orientation
Any
Connection
M23 plug connector, 9-pin
Operating voltage U
B
(reverse polarity protected, regulated, residual ripple < 5%)
20
-
28
V DC
Current consumption (no load on outputs)
-
-
150
mA
External fuse (operating voltage U
B
, +LA and +LB)
0.25
-
10
A
Power supply for load U(+LA)/U(+LB)
U
B
V DC
Safety outputs LA/LB
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U(LA/U(LB)
1)
HIGH U(LA)
U
B
- 1.5
-
U
B
HIGH U(LB)
V DC
LOW U(LA)/U(LB)
0
-
4
Testing of the outputs
- Test pulse length
- Test interval
-
10
-
-
6
-
ms
s
Switching current per safety output
30
-
3,500
mA
Utilization category acc. to EN 60947-5-2
DC-13 24V 3.5A
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
Start input START
V DC
HIGH
8
-
U
B
LOW
0
-
2
Rated insulation voltage U
i
-
-
75
V
Rated impulse withstand voltage U
imp
-
-
1.5
kV
Rated conditional short-circuit current
-
-
100
A
Resilience to vibration
Acc. to EN 60947-5-2
Risk time
-
-
250
ms
Difference time between the two safety outputs
-
-
50
ms
Ready delay
2)
-
-
3
s
Dwell time
3)
0.5
-
-
s
Switching frequency
-
-
1
Hz
Repeat accuracy R acc. to EN IEC 60947-5-3
≤
10
%
Mounting distance between 2 switches or 2 actuators
80
-
-
mm
EMC protection requirements
Acc. to EN 60947-5-3
Reliability values acc. to EN ISO 13849-1
Category
3
Performance Level (PL)
d
PFH
D
1.03 x 10
-7
/ h
Mission time
20
years
1) Values at a switching current of 3.5 A without taking into account the cable lengths.
2) After the operating voltage is switched on, the semiconductor outputs are switched off during the ready delay.
3) The dwell time of an actuator inside and outside the actuating range must be at least 0.5 s to ensure reliable detection of internal faults in the evaluation unit (self-monitoring).