Operating instructions
Non-Contact Safety System CES-A-UEA-02B/CES-A-UEA-04B
14
(Translation of the original operating instructions) 2097098-18-10/19
8.5. Connection example CES-A-UEA-04B
24 VDC
GND
-F1
0V
TST
-F2
UB
CES-A-UEA-04B
097075
J1 J2 SH1
O1
Read-
head
1
H11
Trans-
ponder
O2
H12
EUCHNER
O3
SH2
O4
-V1
Read-
head
2
H21
DIA
Trans-
ponder
H22
-K1
A1
A2
23
SH3
24
-V2
Read-
head
3
H31
Trans-
ponder
13
H32
14
-K2
A1
A2
feedback loop
SH4
Y1
Read-
head
4
H41
Y2
-K2
21
22
-K1
21
22
Trans-
ponder
H42
S
Start
L1
-K1
13
14
-K2
13
14
M
3
~
-M1
L2
23
24
23
24
L3
33
34
33
34
Important!
To achieve category 4 according to EN ISO 13849-1, it is necessary to monitor the downstream
contactors (here: contacts on -K1 and -K2 in the feedback loop).
This example shows only an excerpt that is relevant for the connection of the CES system. The example
illustrated here does not show complete system planning. The user is responsible for safe integration
into the overall system.