Operating instructions
Non-Contact Safety System CES-A-UEA-02B/CES-A-UEA-04B
32
(Translation of the original operating instructions) 2097098-18-10/19
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Nickel-plated CuZn housing sleeve
Plastic PBT GF20 cap
Dimensions
M12 x 1, length 38
mm
Weight (incl. 10 m cable)
0.2
kg
Ambient temperature
-25
-
+85
°C
Ambient pressure
(only of active face in installed condition)
-
-
10
bar
Degree of protection
IP67/IP69/IP69K
Installation orientation
Any
Method of operation
Inductive
Power supply
Via evaluation unit
In combination with actuator CES-A-BMB on evaluation unit CES-A-UEA-…
Assured release distance S
ar
-
-
10
mm
Actuating range for center offset m = 0
1)
- Switch-on distance
-
5
-
- Assured operating distance S
ao
3.5
-
-
- Switching hysteresis
0.1
0.3
-
Connection
M8 plug connector, 3-pin
Connecting cable
-
-
15
m
1) These values apply to surface installation of the read head in steel.
2) A distance of s = 4 mm must be maintained for a side approach direction.
3) A distance of s = 3 mm must be maintained for a side approach direction.