Figure Appendix 1-2: Configure to obtain IP address automatically 

 

Or:  you  can  configure  a  static  IP  address.  Pay  attention,  the  default 

gateway of MR-900T is 192.168.1.1, the IP address set manually should be 

in  the  same  range  (192.168.1.2~192.168.1.254),  for  example, 
192.168.1.20 as shown below: 

Summary of Contents for MR-900T

Page 1: ... 4G Router User Manual eTung Technology Co Ltd 305 Gengfang Plaza Jia 13 Huayuan Road Haidian Dist Beijing TEL 4008 909 611 FAX 010 64857815 Website www etungtech com cn Copyright 2005 2017 ALL RIGHTS RESERVED ...

Page 2: ...supported by the models are listed in the table below Model Network MR 900T W 5 kinds of network standards support China Mobile and China Unicom s 2G 3G 4G networks and China Telecom s 4G network MR 900T C 7 kinds of network standards support China Mobile China Unicom and China Telecom s 2G 3G 4G networks ...

Page 3: ...tion Parameters 19 2 3 Restore to Default 20 2 4 Firmware Update 22 2 5 Remote Configurations 24 Appendix 1 Configure MR 900T for High Speed Internet Connection 31 Appendix 2 eYun Virhub Testing Case to Implement Point to Center Communication 37 Appendix 3 eYun Virhub Testing Case to Implement Point to Point Communication 43 Appendix 4 eYun Vircom Testing Case 48 Appendix 5 Use MR 900T to Access L...

Page 4: ... downlink speed can reach 100Mbps Compared with MR 900W E 3G router MR 900T works in 4G network and has higher data transfer speed it has more reasonable cost control and has lower price than ER 800 4G router It can greatly reduce customer s 4G router procurement cost and is stable and reliable as an industrial wireless router So it is a high cost effective industrial 4G router MR 900T can work in...

Page 5: ... speed wireless applications as well It can work stably and reliably in unattended environment MR 900T can connect quickly with web camera video server PLC and IPC and transfer data from the customer device that connects with MR 900T to a host in the internet so as to transfer data remotely and transparently MR 900T can be widely used in industries such as banking road transportation power system ...

Page 6: ...T User Manual 6 Figure 1 2 MR 900T side view 2 1 3 Standard Accessories Figure 1 3 4G all frequency sucking antenna SIM Card Slot Indication Lights Console Reset to Default Button Antenna Installation Handle ...

Page 7: ...MR 900T User Manual 7 Figure 1 4 Cross cable Figure 1 5 9 pin and 9 hole direct serial line ...

Page 8: ...MR 900T User Manual 8 Figure 1 6 Power supply ...

Page 9: ...MR 900T User Manual 9 1 4 Dimension Figure 1 7 MR 900T dimension with shell ...

Page 10: ...o build remote virtual LAN with Virhub or VPN monitor video remotely and publish programs remotely on LED color screens etc 1 6 Specifications 1 6 1 Technical Parameters Basic Parameters Power Supply 9 36V wide range of voltage input Power Connector inner outer Max Current 230mA 12V DC Standby Current 130mA 12V DC Data Interface RS232 RJ45 Network MR 900T W LTE TDD LTE FDD TD SCDMA HSPA UMTS EDGE ...

Page 11: ...ding Support DMZ host IP address mapping Support VPN Support dynamic domain auto registration Support configuring static route table Support real time speed display of wireless network Support displaying network standards 4G 3G 2G Support switching network automatically Support configuring with serial port telnet and web interface Support serial port DTU function Ethernet and serial interfaces can...

Page 12: ...m its reliability Its technical advantages are easy to see Support 4G LTE TDD LTE FDD and 3G 2G networks Support network switch automatically Support dynamic domain auto registration domain resolving software is not needed Support serial port Telnet and web configuration Support VPN to build virtual LAN and simply change fixed line to wireless line Support serial port DTU function Ethernet and ser...

Page 13: ...MR 900T User Manual 13 1 8 Typical Usecases Figure 1 9 Access Internet via 3G router Figure 1 10 Use MR 900T Ethernet and serial interfaces at the same time ...

Page 14: ...MR 900T User Manual 14 Figure 1 11 Implement virtual LAN via MR 900T s Virhub functionality point to center Figure 1 12 Use MR 900T to access LAN remotely via VPN ...

Page 15: ...e Configurations 2 1 Configurations 2 1 1 Preparation One cross Ethernet cable used to connect MR 900T with PC or customer device One 4G all frequency sucking antenna One power supply One USIM card for example China Mobile and that can access internet 2 1 2 Configuring MR 900T Connect MR 900T with PC via a cross Ethernet cable Boot PC and set IP address as Automatically obtain IP address ...

Page 16: ...MR 900T User Manual 16 ...

Page 17: ...tically obtain IP address Open IE browser input address http 192 168 1 1 and press Enter Input root as username and 1234 as password then press Enter to login web configuration interface and configure the device Figure 2 2 Login router configuration interface ...

Page 18: ...onfiguration item in the router configuration interface To change some parameter click it modify and then save it then reboot the router Keep the default configurations if the router is used only to access internet Figure 2 3 Router s current status ...

Page 19: ...ter can access internet via NAT Port Mapping Use pre defined port to forward data from internet to some inner IP s dedicated port DMZ host Forward data from internet directly to some inner IP Router Forward data to a pre defined inner IP DDNS Domain resolving function configure the router to have a static domain to be easily accessed VPN PPTP L2TP Login with username and password to connect VPN GR...

Page 20: ...re Update router s firmware Change Password Change password logging router 1234 by default Import or Export config Import parameter file saved before Export current configurations to file Reboot Reboot router Table 2 1 Details of configuration parameters 2 3 Restore to Default According to the description of Configuring MR 900T after entering MR 900T configuration interface select System Tools and...

Page 21: ...900T is started hold the button Reset to default with a sharp object do not release the button until Online light flashes two or three times and then always lights that means the router has been reset to default and is rebooting automatically ...

Page 22: ...ernet cable input username and password by default username is root and password is 1234 and login router configuration interface Select System tools and then Upgrade Firmware click Browse select the file img to update and click Open then click Upload Figure 2 5 Select file to update Click Update after upload is complete It s better to select Delete the Former File ...

Page 23: ...MR 900T User Manual 23 Figure 2 6 Firmware Update After update is complete the device will reboot automatically and it will show as in the figure below Figure 2 7 Update complete ...

Page 24: ...nd and some command fails the following commands will not be executed If a command is unknown an ERROR will return The commands will take effect after system reboot This can be done by putting a command AT REBOOT in the end of SMS commands or sending a separate SMS with command AT REBOOT 3 AT command must be capitalized but the parameters in the command do not have this limit 4 If there are multip...

Page 25: ...main port data center port user username mode TCP or UDP 3 AT PWD passwd Set new SMS password with at most 8 characters exluding etc It is adviced to use digits and English characters only The reply is OK or ERROR 4 AT VIRHUB 0 1 Set whether to enabe Virhub or not with reply OK or ERROR 0 disable Virhub 1 enable Virhub 5 AT RESTORE Restore to default settings with reply OK 6 AT REBOOT Reboot the d...

Page 26: ...cess this url for example it should not be a public URL if the device has a private net card 14 AT UPDATEALL url Update firmware and restore to default settings with reply OK or ERROR url download URL of the new firmware beginning with http Make sure the device can access this url 15 AT SMSZHUANFA txt info_src dest Ask the router to send an SMS to info_src first with content txt only in English ch...

Page 27: ... will show in CMD Response on the right side Then MR 900T will be offline from the original mServer and connect to the new data center and port Remote AT commands are listed below 1 AT 2 AT MSERVER addr port Change data center address and port with reply OK or ERROR addr data center address either IP address or domain port data center port 3 AT USER user Change DTU username with reply OK or ERROR ...

Page 28: ...ake sure the device can access this url for example it should not be a public URL if the device has a private net card 7 AT UPDATEALL url md5 Update firmware and restore to default settings with reply OK or ERROR url download URL of the new firmware beginning with http Make sure the device can access this url 8 AT DTU IMEI Query the router s IMEI number with the following reply OK IMEI 9 AT DTU VE...

Page 29: ...function 17 AT CM TYPE prot Set protocol type with reply OK prot TCP UDP ETCP 18 AT CM HBI interval Set heartbeat interval in seconds with reply OK 19 AT CM HBT timeout Set heartbeat timeout in seconds with reply OK 20 AT SER BAUD baud Set user serial port baud rate with reply OK Baud 2400 4800 9600 19200 38400 57600 115200 21 AT SER SIZE size Set user serial port data bit with reply OK Size 8 7 6...

Page 30: ...forward the reply to 13801234567 MR 900T V1 4 9 or higher versions additionally support the following remote AT commands 26 AT VIRHUB TAP_IP Check the remote access IP address via Virhub with reply OK x x x x 27 AT VIRHUB TAP_MASK Check the remote access netmask via Virhub with reply OK x x x x 28 AT VIRHUB TAP_IP x x x x Set the remote access IP address via Virhub with reply OK 29 AT VIRHUB TAP_M...

Page 31: ...Cs can share internet access via MR 900T Below we will illustrate these two kinds of internet access one by one 1 PC directly connects with MR 900T to access internet Figure Appendix 1 1 PC accesses internet via MR 900T Steps 1 Connect PC with MR 900T via a cross Ethernet cable 2 Configure IP on PC as Automatically obtain IP address Click Control Panel Network Connection Local Connection then righ...

Page 32: ...MR 900T User Manual 32 ...

Page 33: ...o obtain IP address automatically Or you can configure a static IP address Pay attention the default gateway of MR 900T is 192 168 1 1 the IP address set manually should be in the same range 192 168 1 2 192 168 1 254 for example 192 168 1 20 as shown below ...

Page 34: ...utomatically and after dialing is successful you can browse webpage and send receive emails via PC The dialing status of MR 900T can be checked in the web interface Just input http 192 168 1 1 MR 900T s default gateway is 192 168 1 1 in IE then input default username root and password 1234 you can then check the working status as well as current connection speed and flow of MR 900T ...

Page 35: ...Cs sharing internet access connect to the down link of switch hub with Ethernet cables 2 Configure IP address as automatically obtain IP address or set IP address manually as shown above 3 Plug a USIM card for example China Mobile and with internet service into MR 900T then after power on MR 900T will dial automatically and after dialing is successful you can browse webpage and send receive emails...

Page 36: ...assword 1234 you can then check the working status as well as current connection speed and flow of MR 900T Figure Appendix 1 6 4G router s network connection status MR 900T wireless router has functions such as port forwarding DMZ host and DHCP service so customers can define data forwarding rules on MR 900T as on a generic router ...

Page 37: ...g virhub software on PC a virtual Ethernet adapter is installed at the same time and after installation set the IP address of the virtual adapter in the same IP range as the IP address of the user device Then 4G router eYun Virhub can be regarded as an infinite net cable that connects user device and PC at the monitoring center the PC and user device can be regarded as in the same virtual LAN and ...

Page 38: ...onfiguration enter Virhub configuration menu and select Virhub input the username applied above and click Save then reboot the router Figure Appendix 2 3 Enable Virhub function 3 Install Virhub software Ask wireless Virhub v5 x installation package from eTung install it according to Virhub s installation guide ...

Page 39: ...ub 2 Configure Microsoft Loopback adapter s IP address in the Settings dialog we can set Loopback adapter s IP address in Loopback Adapter IP Settings IP1 is used to build a virtual LAN with the front end device i e the Webcam and it has to be in the same IP range as the front end device s IP for example 192 168 10 Figure Appendix 2 5 Configure Loopback adapter s IP address ...

Page 40: ...Tung s Virhub solution can solve the problem First enable Virhub function on the router and set a remote access IP the remote access IP is dedicated to access the router remotely when Virhub is enabled on the router Then run Virhub software on the far end PC and configure an IP address on the Loopback adapter this IP must be in the same range as the remote access IP on the router This way we can a...

Page 41: ...urations 2 Configure the Loopback adapter s IP address to access the router remotely Run Virhub software click button Configure and on the popped up Settings dialog set the Loopback adapter s IP address in Loopback Adapter IP Settings part IP2 is the IP address set on the Loopback adapter to access the router remotely via Virhub and this IP must be in the same range as the Remote Access IP 192 168...

Page 42: ...er 3 Access the router remotely Open browser and input the router s remote access IP 192 168 168 1 by default and then the router s web configuration page shows Figure Appendix 2 9 Access the router s Web configuration page remotely Then we can login the web page to change the router s parameters remotely just as the router is directly connected locally ...

Page 43: ...s User devices connect to wireless routers with RJ45 Ethernet cable and wireless routers connect to Internet via 3G 4G network and establish connection with eYun server on the Internet On the monitoring center run virhub software on the PC and add mapping for the routers that connect to user devices which need to communicate each other Set IP address for the user devices in the same IP range Then ...

Page 44: ...nt 2 Configure IP address for user devices Set the IP address of the two devices in the same IP range for example 192 168 10 as shown in figure appendix 3 1 192 168 10 10 and 192 168 10 20 respectively 3 Configure Virhub parameters Refer chapter 2 Configuration enter Virhub configuration menu and select Virhub input the username applied above and click Save then reboot the router ...

Page 45: ...r versions support this function 5 Login in Virhub and start data transfer 4 Run Virhub and click Settings input the username and password applied before Figure Appendix 3 4 Login Virhub 5 Configure Microsoft Loopback adapter s IP address in the Settings dialog we can set Loopback adapter s IP address in Loopback Adapter IP Settings IP1 is used to build a virtual LAN with the front end device i e ...

Page 46: ... to add user device to the virtual LAN then the user devices can communicate each other directly For example use ping command in one device to ping the other device can work and vice versa By default Virhub will automatically add all terminals under the username into the virtual LAN and if you need to test only two of them please delete the mapping for other terminals just choose the terminal and ...

Page 47: ...MR 900T User Manual 47 Figure Appendix 3 6 Add Virhub PC to virtual LAN ...

Page 48: ...d transparent data transmission eYun platform and Vircom functionality make it easier to implement remote access of serial devices Below we will illustrate the implementation in detail Figure Appendix 4 1 Router connects serial devices 1 Apply eYun account Access website http eyun etungtech com apply an eYun account and then contact technical support to open this account ...

Page 49: ...enu DTU Function Simple cfg and then set Main DC IP as eyun etungtech com and Main DC Port as 8080 Account as the eYun account applied before In User Serial Configuration the parameters values must be the same as those configured in the serial device that the router connects to and if they are not the same we can modify the values here in the router to make sure they are the same ...

Page 50: ...x 4 3 Configure DTU parameters After the configuration is complete click Save and then reboot the router After a while it can be seen in Status page that the router has connected to the data center Figure Appendix 4 4 Check router s status ...

Page 51: ...hen input the username and password applied before Figure Appendix 4 5 Login Vircom Find the device to be tested via IMEI and click Add Mapping to map this device to a virtual serial port Then open this virtual serial port with relevant software to communicate with the devices that connect to the router ...

Page 52: ...MR 900T User Manual 52 Figure Appendix 4 6 Map virtual serial port in Vircom ...

Page 53: ...MR 900T to access LAN remotely via VPN 2 Preparations 1 One router with VPN function use PPTP protocol as an example a LAN is attached to this router and can access internet 2 One MR 900T including accessories 3 One USIM card with internet service for example China Mobile and 4 One PC 3 Steps 1 Configure to use PPTP when accessing the router Here we use router RV042 from linksys as an example Firs...

Page 54: ...outer s VPN function Actually different routers have different configuration interface and options we can configure it accordingly 2 Configure MR 900T Login MR 900T s configuration interface click VPN function and configure it as shown in the figure below ...

Page 55: ...e domain here MR 900T supports domain resolving Username the username configured in the router at corporate LAN side i e the username configured in linksys router before Password the password configured in the router at corporate LAN side i e the password configured in linksys router before VPN function ON to enable VPN connection After all settings are complete reboot MR 900T 3 Check dialing stat...

Page 56: ...e corporate LAN and then access the video monitoring interface Notes 1 The IP address used by PC or video server that is connected to MR 900T must not be in the same range as those IP addresses at the corporate LAN side For example if the IP range at the corporate LAN side is 192 168 0 then MR 900T should be in other IP range for example 192 168 1 2 MR 900T and the PC or video server that connects...

Page 57: ...ost There are two kinds of solutions to use APN networks and below are details for each of them Solution 1 Embedded Data Center with APN Network eTung s wireless routers support APN SIM card and has embedded data center function For those small scale projects with few terminals use one router as the data center and dial into APN network at the same time all other terminals that connect to devices ...

Page 58: ...b page Choose Wireless Net Simple Cfg and then select Manual Set for APN Mode configure APN name and PPP username and password if required Click Save and then reboot the router to apply the change Figure Appendix 6 2 Configure APN parameters in the router 2 Configure Embedded Data Center in the router Login the router s configuration web page choose DTU Function Embedded DC enable embedded DC set ...

Page 59: ...address acquired from APN network 3 Configure data center address and APN parameters in DTU Run wireless configuration software dtucfg exe power on DTU according to the prompt and then enter the configuration menu For the 1st item mServer DN IP Addr set as the static IP address acquired by the router from APN network for example 10 8 224 81 for the 2nd item mServer Port set as 9000 for the 4th ite...

Page 60: ...PN SIM card as required Figure Appendix 6 5 Configure DC address and APN parameters in DTU After that press Enter until the serial port parameters baud rate data bits parity stop bits and flow control the values for these parameters must be the same as those set in the serial device that DTU connects to and if they are not the same we can modify the values here in DTU to make sure they are the sam...

Page 61: ...serial port parameters After configuration is finished reboot DTU to dial up into APN network it will then automatically connect to the router s embedded data center in the router s status page we can see that one device has connected the embedded data center ...

Page 62: ...are received sent Solution 2 mServer Connects the Router and with APN Network For large scale projects with lots of terminals this solution mServer connects the router and with APN network can be used As shown in the figure below eTung s wireless router dials into operator s APN network and the data center at the back end connects to the router with Ethernet cable at the same time configure DMZ ho...

Page 63: ...name and password and for the SIM card used by the router there should be a static IP address assigned as well 1 Install and run mServer in the data center server Ask eTung for mServer installer and install mServer according the user manual Make sure the firewall software allows accessing mServer from outside After mServer is installed double click mServer s icon on the desktop to run mServer cons...

Page 64: ... 3 Configure DMZ host in the router First connect data center server to the router with Ethernet cable Then set static IP address in the data center server and the IP address must be in the same IP range as the IP address of the router s Ethernet interface for example 192 168 1 The figure below shows the server s static IP address is set to 192 168 1 100 and gateway and DNS are set to 192 168 1 1 ...

Page 65: ...re Appendix 6 10 Set static IP address Login the router s web configuration page choose NAT Rule DMZ Host then configure DMZ Host IP as the static IP address of the data center server for example 192 168 1 100 as configured above ...

Page 66: ... center address and APN parameters as shown in step 3 of solution one Set data center IP address to the IP address acquired by the router after dialing into the network and data center port as mServer s listening port i e 9000 as shown in Figure Appendix 6 9 After configuration is complete reboot DTU it will dial into APN network and then connect to mServer in mServer s console we can see that thi...

Page 67: ... 900T User Manual 67 After DTU connects to the data center the application software at the front end will then be able to communicate with the devices at the far end via virtual serial port or other ways ...

Page 68: ...mat MR 900T supports sending receiving SMSs via Ethernet interface The method is described below First establish a TCP connection with the router s Ethernet IP 192 168 1 1 by default and port 8888 then use command AT SMS or AT SMSA to send SMSs For example use TCP Test Tool to send SMS as shown below ...

Page 69: ...ening port 2 Input AT SMS or AT SMSA command in box Edit Send Data and pay attention to end with CR then click send if OK is shown in box Edit Data Log that means the command has been sent successfully NOTE 1 Currently only MR 900T v1 4 5 or higher version supports sending receiving SMSs via Ethernet interface 2 Currently receiving long SMSs is supported but sending long SMSs is not supported i e ...

Page 70: ... nERROR r n Target Number Phone number to receive the short message Encoding Format 1 ASCII encoding 2 8bit encoding 3 Unicode encoding Data Length The actual data length behind Data The data to be sent each byte should be formatted to a 2 byte hexadecimal number for instance 1234 should be written as 31323334 Examples Send 1234 with ASCII encoding to 13812345678 AT SMS 13812345678 1 4 31323334 r ...

Page 71: ...elow is the fourth message r n SMSAL 05000376 4 4 10001 6 123456 2 Format for SMS messages received with encodings other than ASCII If the content of received SMSs is not in ASCII encoding for example with Chinese characters the output is in the following format r n SMS phone number encoding format data length data r n Examples 1234 received from 13812345678 in 8bit encoding r n SMS 13812345678 2 ...

Page 72: ...s and choose DTU function Simple Cfg to set parameters for user serial port including baud rate data bits parity stop bits and flow control by default they are 9600 8 No parity 1 and No flow control Make sure that the values of these parameters are set the same both on the user device and on the router Click Save after change and reboot the router Figure Appendix 8 1 Configure router s serial port...

Page 73: ...anwhile the router can receive and output SMSs from the user serial port as shown below Figure Appendix 8 3 Receive and output SMS via router s serial port NOTE 1 Currently only MR 900T v1 6 5 or higher version supports sending receiving SMSs via user serial port 2 The router s user serial port is standard RS232 DB9 female interface and if the user device s serial port is also DB9 female interface...

Page 74: ...he length of messages in English cannot exceed 160 characters and the length of messages in Chinese cannot exceed 70 words 4 AT commands must end with CR 0x0d expressed below as r The AT commands to send receive SMSs are described in Appendix 7 Send Receive SMS with the Router s Ethernet Interface and SMS Format ...

Page 75: ...ease refer the descriptions of AT commands via SMS in 2 5 Remote Configurations 1 AT WN apn user passwd net_mode r 2 AT DC addr port user mode r 3 AT PWD passwd r 4 AT VIRHUB 0 1 r 5 AT RESTORE r 6 AT REBOOT r 7 AT STATUS r 8 AT WN r 9 AT DC r 10 AT INFO r 11 AT VIRHUB r 12 AT UPDATE url r 13 AT UPDATEALL url r Following are the AT commands used to send SMS for details please refer Appendix 7 Send...

Page 76: ...MR 900T User Manual 76 17 AT DISCCOUNT YYYYMMDD r Get the disconnection times in the specified date the date format is YYYYMMDD and the reply is the times of disconnection during that day ...

Reviews: