Legend 548 Assembly and User Manual - 41
30068-02A
Care and Maintenance
Cleaning After Use
Clean and disinfect your tanning bed’s bench
and canopy after each use. Use a non-abra-
sive disinfectant cleaner that does not con-
tain ammonia or ammonia derivatives. Am-
monia may damage the acrylic shield. Spray
the acrylic lightly with disinfectant and wipe
dry with a clean soft cloth. We recommend
Australian Gold® pH Neutral Disinfectant
Cleaner.
Thorough Periodic Cleaning
The cooling fans draw air through the bed
and over time will cause a dust buildup on
the lamps and re
fl
ectors. This will reduce
the tanning effectiveness of the bed. When
a dust buildup is observed, it is necessary
to thoroughly clean the inside of the bench
and canopy.
Cleaning the Canopy and Bench
Open the acrylics and remove lamps as
1.
described on the next page.
With a soft cloth, wipe the entire length
2.
of each lamp to remove any
fi
lm build-
up.
Clean both sides of the acrylics with a
3.
non-ammonia disinfectant cleaner.
Wipe the re
fl
ectors with a clean damp
4.
cloth.
Reinstall the lamps and acrylics.
5.
Use a vacuum cleaner to clean all fan
6.
openings.
Mechanical Inspection
Your tanning bed has been built for years
of service. To ensure trouble-free operation
throughout its life, inspect the unit’s me-
chanical integrity every 400-500 hours of
use.
Inspect the unit’s fasteners verifying that
•
all are
fi
rmly in place.
Inspect the lift system for proper opera-
•
tion. The canopy should raise and lower
with minimal effort using the canopy
handle. Contact a servicer to adjust or
replace if necessary.
Inspect all wiring connections. Contact a
•
servicer if any connections seem loose.
Inspect the AC power cord and its con-
•
nections.
Inspect the acrylic. Broken, cracked or
•
badly scratched acrylics should be im-
mediately replaced.
Shock hazard.
Disconnect power before removing
any protective covers.