28937-01A
19
are and Maintenance
Cleaning After Use
Clean and disinfect your tanning bed’s
bench and canopy after each use. Use a
non-abrasive disinfectant cleaner that
does
not contain ammonia or ammonia deriva-
tives
. Ammonia may damage the acrylic
shield. Spray the acrylic lightly with disin-
fectant and wipe dry with a clean soft cloth.
We recommend Australian Gold® pH
Neutral Disinfectant Cleaner.
Thorough Periodic Cleaning
Introduction
The cooling fans draw air through the bed
and over time will cause a dust buildup on
the lamps and reflectors. This reduces the
tanning effectiveness of the bed. When a
dust buildup is observed, it is necessary to
thoroughly clean the inside of the unit.
Cleaning the Canopy and Bench
Step 1
Remove the acrylic shields and
lamps as described in
Lamp and
Acrylic Replacement
.
Step 2
With a soft cloth, wipe the entire
length of each lamp.
Step 3
Clean both sides of the acrylic
shields with a non-ammonia dis-
infectant cleaner.
Step 4
Wipe the reflectors with a clean
damp cloth.
Step 5
Reinstall the lamps and acrylic
shields.
Step 6
Clean or replace air filters on top
of ballast tray and under bench
(see
Final Adjustments
). Replace
with 10” x 24” x 1” furnace filters.
Mechanical Inspection
Your tanning bed has been built for years of
service. To ensure trouble-free operation
throughout its life, inspect the unit’s mechan-
ical integrity every 400-500 hours of use.
• Inspect the unit’s fasteners verifying that
all are firmly in place.
• Inspect lift springs for signs of wear.
Adjust for proper lift if needed. See
Final
Adjustments
.
• Inspect the AC power cord and its con-
nections.
• Inspect the acrylic. Broken, cracked or
badly scratched acrylics should be
immediately replaced.
• Check damper operation. The damper
limits the canopy’s movement speed.
Replace if canopy raises and lowers too
quickly.
WARNING
Shock hazard.
Disconnect power before removing
any protective covers.