28937-01A
Page 1: ...28937 01A...
Page 2: ...NCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY DISCLAIMED No one has the authority to change or modify this 48 Month Gold Medal Warranty in an...
Page 3: ...erve all safety precautions ontents Safety Information iii Installation 1 Unpacking and Inspection 1 Tools Required 1 Pre Installation Planning 2 Hardware Inventory 3 Assembly Procedures 4 Electrical...
Page 4: ...therefore be reduced by approximately 10 during that period WARNING Read the instructions booklet before using this sunlamp product All persons in the room should wear protective eyewear when lamps ar...
Page 5: ...ont d j un teint h l peuvent commencer des niveaux plus lev s selon l importance de leur h le initial Les lampes neuves mettent approximativement 10 de plus de rayons ultraviolets au cours des 50 pre...
Page 6: ...hem for future use After unpacking the unit check to make sure you have received the following Canopy unit Bench unit Ballast tray Metal access panel Long metal hinge cover panel Two large endcaps Bod...
Page 7: ...the bed is assembled reinstall the bar to keep the tray from damaging the access panel if the bed is moved WARNING Shock hazard Disconnect power before servicing Air from the room is used to cool the...
Page 8: ...ble make sure you have the following hard ware items Safety Goggles Quantity 1 Access Panel Key Quantity 1 10 x 1 Phillips Pan Head Screw Quantity 14 3 8 16 x 1 1 4 Hex Socket Bolt Quantity 6 3 8 16 S...
Page 9: ...lling the foot end endcap you must install the body fan power cord into the endcap as shown below The connec tor will snap securely into the endcap The body fan kit includes instructions for installat...
Page 10: ...n Assembly Procedures Parts needed Head end endcap Foot end endcap 14 10 x 1 Phillips pan head screws 4 10 x 1 2 Phillips pan head screws Attach each endcap with 7 1 screws as shown Foot end endcap sh...
Page 11: ...28937 01A 6 Installation Assembly Procedures Use the preinstalled screws to attach the hinge cover panel Parts needed Long blue hinge cover panel...
Page 12: ...m onto hinge arm Positioning bolt will engage the slot on top of hinge arm and hold canopy up while the other bolts are installed Install other bolts as shown Secure all six bolts in place with self l...
Page 13: ...ssembly Procedures Put access panel in place and lock with access panel key Install Body Fan Instructions are included in Body Fan kit Slide ballast tray under and pull cords through to the back Reins...
Page 14: ...ne type cable between the canopy and rear jack on the ballast drawer The three jacks on the front of the drawer are for remote connections Connect main power cord as described in Pre Installation Plan...
Page 15: ...aped Lift Adjustment lugs shown below clockwise for more lift and coun terclockwise for less When adjusted properly the canopy should raise easily as well as rest fully closed Always adjust both lugs...
Page 16: ...e of the RJ 22 remote control ports Your sunbed will not operate without the Remote Control Bypass plug or a remote system connected ATTENTION Although the Remote Control Bypass plug provided with you...
Page 17: ...dressing feature of the latest T Max Manager models and the following parameters 5 6 7 8 9 10 15 and 23 See your T Max manual for descriptions of these parameters and how they function REMOTE PORTS WI...
Page 18: ...ngle sunbed installations the T Max 1A and 3A can offer the same control as the T Max Manager eliminating the need for a Manager If you re using a 1A in this manner it must have a chip labelled master...
Page 19: ...the salon may be daisy chained together and connected to the Manager Scenario 5 T Max Manager Series with wires As always this tanning bed is fully com patible with a wired T Max system Simply con nec...
Page 20: ...tration below details a typical connection Follow the instructions provid ed with the kit and from the remote s manual to make the necessary connections Setting the sunbed address manually Before conn...
Page 21: ...tan more than once a day Tanning normally appears after the first few sessions and maximizes after approxi mately four weeks Tan once or twice per week thereafter to maintain appearance Persons alread...
Page 22: ...se the canopy by using the canopy handle do not push up on the acrylic shield The cooling fans run for a period of time after the lamps shut off to aid in cool ing the sunbed The timer will indicate a...
Page 23: ...time expires press the stop button E You will have ten seconds to restart with the remaining time otherwise the timer will reset to 0 6 Raise the canopy by using the canopy handle do not push up on th...
Page 24: ...entire length of each lamp Step 3 Clean both sides of the acrylic shields with a non ammonia dis infectant cleaner Step 4 Wipe the reflectors with a clean damp cloth Step 5 Reinstall the lamps and acr...
Page 25: ...s etc When finished simply close the canopy to return to normal operation Opening Replacing Acrylic Shields Refer to the illustration on the next page while reading this instruction The acrylic shield...
Page 26: ...28937 01A 21 Care and Maintenance Lamp and Acrylic Replacement CANOPY ACRYLIC BENCH ACRYLIC ACRYLIC SUPPORT Body fan deleted for clarity...
Page 27: ...s a viola tion of Federal regulations and will void your warranty These lamps have an aver age life of 600 800 hours of effective tan ning use Lamps used longer than that begin to lose their effective...
Page 28: ...e that the lamp is firmly seated in the lamp holders Note Never take hold of the lamp such that your fingers are in contact with the lamp glass Finger oils will greatly reduce the lamp s operational l...
Page 29: ...he current minute is subtracted from the last minute 1 Check that lamp is installed correctly 2 Switch unlit lamp with a lamp that lights if new lamp lights and old lamp still does not replace old lam...
Page 30: ...Contact servicer Current sensor indicating unit is on when it should be off Contact servicer Requested session time exceeds maximum time allowed 1 Bypass plug is not installed see Electrical Connecti...
Page 31: ...ce has not been set 2 The sunbed has not been connected to the remote system see Remote Connections 1 Delay time of T Max Manager has not been set 2 Delay time has expired and session has begun Auto s...
Page 32: ...28937 01A T 542 3F...
Page 33: ...28937 01A Ballast Tray...
Page 34: ...nopy Foot End Endcap Canopy Head End Fan 6 Fan Body Fan Cooling Fan Relay Filter Handle Kit Hardware Kit Hinge Cover Panel Hour Counter Ignitor face tanner starter Lamp Holder w Starter Lamp Holder w...
Page 35: ...terior E Check Clean Fans F Change Lamps H Check Fasteners nuts bolts etc I Check Power Cords J Change Filters See Care and Maintenance See Lamp and Grill Replacement Fans are located on top of the ca...
Page 36: ...ch BRONZING SUN PLUS Main Lamps canopy Velocity VS R Ballasts 100W bench 160W canopy Face Tanner SolarMax IFT FT Ballasts 400W Cooling System 825cfm body fan Timer System Digital Max Exposure Time 12...