Next, while supporting each Ozone Module, release its four (4) clamps that fasten it in place. While carefully
lowering the module, locate and disconnect the pressure measurement hose from the inside the 100mm exhaust
hole.
Remove the OZ bottom cover
Remove the bottom cover by removing
four (4) M5x12 bolts from the side panel
and keep them in a secure place for later
use
.
4x