EN 52
ERROR CODES
Error code
General functions
ERROR TEMPERATURE SENSOR OPEN
This error occurs if there is a faulty sensor, incorrect connections, a
faulty PCB and if the A/D value detected by MICOM is lower than 10 .
ERROR TEMPERATURE SENSOR SHORT
This error occurs if there is a faulty sensor, incorrect connections, a
faulty PCB and if the A/D value detected by MICOM is higher than 252 .
TARGET TEMPERATURE TEMPERATURE SENSOR
This error occurs if the preheating was not completed and the
temperature in the oven is lower than 120 °C for 30 minutes .
ERROR ABNORMAL TEMPERATURE DETECTION
This error occurs if the temperature in the oven is higher than 250 °C for
10 minutes .
ERROR ABNORMAL TEMPERATURE DETECTION MICROWAVE
This error occurs if the temperature in the oven in the microwave setting
is higher than 210 °C .
ERROR BUTTON SHORT
This error occurs if you press and hold a button for longer than
60 seconds .
This error may occur if water gets into the control panel or if dust
particles stick on theTOUCH PANEL .
ERROR NAK SIGNAL
The NAK signal is given if it takes longer than 10 seconds to switch on
the appliance .
COMMUNICATION ERROR
This error occurs if there is no communication between the main PCB
and the sub PCB for longer than 10 seconds .
ERROR EEPROM OPEN
This error occurs if something goes wrong in the EEPROM
communication when you are setting the power .
ERROR EEPROM READ & WRITE
Eeprom is not used .
If one of these errors occurs, contact the Etna customer service .