background image

1. Unscrew the sensor cover in the direction shown (Fig 1.).
2. Screw the sensor into the bottom of the sensor to complete the installation (Fig 2. ) (Improper installation may cause waterproof failure);
3. Test Light.

On / Off

Control

Detection

Area

Hold

Time

Daylight

Threshold

Stand-by

Period

Stand-by

Dimming Level

Remote Control

Setting

10-15M

High Bay

Altitude

Head Offi ce -

 1850 Wilson Ave. · Toronto, ON · M9M 1A1 · 

Tel:

 416.741.7336 · 

Fax:

 416.741.9104 

Toll free:

 in Canada. 1.800.661.9610 · in USA. 1.888.762.5384 (SOCKETS4U)

www.etlin-daniels.com· For sales/service questions - [email protected] 

SAVE THESE INSTRUCTIONS - READ ALL INSTRUCTIONS CAREFULLY

SENSOR INSTALLATION

FIG .1

FIG .2

APPLICATION ENVIRONMENT.

1. Suitable only for indoor applications.
2. Not suitable for spaces where all walls are metal or with metal roofing.
3. Not to be installed in close proximity to large machinery like ventilators, ceiling fans, to avoid false triggering due to 
machine vibrations.

INSTALLATION PRECAUTIONS.

1. The areas of detection cannot be shielded by metal objects.
2. Ensure the Microwave Sensor is properly secured to ensure Watertight seal.

OVERVIEW

• Automatic On / Off control with Daylight Sensor
• Optional detection range, holdtime, daylight threshold, Standby period and standby dimming level.
• Remote control settings available.

HBRA7 – INSTALLATION GUIDE MICROWAVE SENSOR

USER NOTES.

1. The Microwave Sensor can penetrate walls or glass thinner than 20cm, and will be weaker if the surface is thicker than 20cm.
2. The detection area will be affected by speed of motion, mounting height, and movement volume

3. The detection surface of the sensor shall be installed facing the detection area.
4. Wiring must be in accordance with the wiring diagram to avoid short circuit.

15m

5

years

INSTALLATION FOR HBRA7 SERIES ROUND WITH

 MICROWAVE SENSOR BASE HIGH BAY