7 MALFUNCTIONS
7�1 Possible causes of the following malfunctions:
Device does not heat up:
– Circuit breaker triggered or defective
– External switch in the supply line
switched off
– Target temperature of the thermostat
is set at a value lower than the
actual temperature of the room
– Temperature of the temperature lim-
iter in the network heating mat
exceeded
Radiating heat too low:
– Distance between radiant heater and
person too large
– Obstructing object located between
radiant heater and person
8 COMMISSIONING
NOTE
Keep measurement record with the
device.
NOTE
After the plaster or tile adhesive has
hardened (observe manufacturer's
instructions) and at the earliest after
24 hours, the heating can be put into
operation.
The following documents must be handed over
to the operator or permanently stored in the
electrical distribution system:
• Technical documentation including accom-
panying documents
9 ENERGY CONSUMPTION
In conjunction with an ecodesign-compliant
thermostat, the product data conform to the EU
regulations for
environmentally sound design of energy-related
products (ErP).
10 DISPOSAL
Old electrical and electronic appliances often
contain valuable materials. However, they may
also contain harmful substances that were nec-
essary for their function and safety. Disposed of
with the non-recyclable waste or due to incor-
rect treatment, these substances can damage
the environment. Please help us protect the
environment!
Therefore, never dispose of your old appliance
in the residual waste (non-recyclable waste).
Ensure that your old appliance is disposed of in
accordance with local regulations. Dispose of
packaging material, later replacement parts or
device parts properly.
23
23
DE
EN
FR
NL
IT