![Etherma ETZ-230-1CR Operating And Assembly Instructions Manual Download Page 18](http://html1.mh-extra.com/html/etherma/etz-230-1cr/etz-230-1cr_operating-and-assembly-instructions-manual_2432559018.webp)
3 PRODUCT DESCRIPTION
3�1 Scope of delivery
Your product contains the following compo-
nents.
Grid heating mat, 1 unit
Dummy screws, 2 units
Mounting rail, 1 unit
Thermostat, 1 unit
Towel rail
*)
, 1 unit
Insulating panel, 2 units
*)
The scope of delivery includes 1 towel rail.
Optionally, up to 3 more
towel rails (each with 2 dummy
screws) can be installed.
Retrofitting at a later date is not possible.
Additional applicable documents:
• Installation instructions for towel rail
• Operating instructions for thermostat
• Warning sticker for electrical cabinet
• Measurement record
4 TECHNICAL DATA
General
Type
ETZ-230-1CR
Voltage:
230 V
Output
230 W
Dimensions (L x W x H)
Mounting rail
490 × 90 × 30 mm
Insulating panels
850 × 600 × 6 mm
Grid heating mat
1250 × 400 × 3.3 mm
Wall covering
Flexible adhesive
Cover for heating element:
≥
5 mm
Clay plaster
Cover for heating element:
≥
20 mm
Fig. 1: Scope of delivery - Product overview
The power supply must be
protected by a residual cur-
rent device with a maximum
current of 30 mA and a circuit
breaker with a maximum
current of 16 A (according to
DIN VDE 0100 part 753).
Type plate
18
18