For the motor wiring, refer to the EN 60204/1 or NEC (UL) standard in order to use the
adequate cable section.
The DSC2P housed format already includes an in-built filter. An additional filter can be added
(for example (Schaffner FN2070-16-06) or a 'common mode choke' of 3mH (Schaffner
RD6127-16-3m0)) to reduce further electromagnetic disturbances.
For safety reasons, always connect first the protective earth (PE) to the screw under the DSC2P!
Remark:
The tightening torque for the screws of the power input connector is 0.6 Nm max.
3.5.3
Connector JC12: Housed format, auxiliary supply input
This connector is only present on the DSC2Pxx
4
-xxx controller.
For safety reasons, always connect first the protective earth (PE) to the screw under the DSC2P!
Remark:
The tightening torque for the screws of the auxiliary input connector is 0.25 Nm max.
•
The
power stage relay
(24 VDC / 2880
Ω
) allows the user to cut the +15 VDC voltage supplying the IGBT
gate driver, when the +24 VDC supply input of this relay is stopped.
If the power stage relay is not powered, the IGBT gate driver is deactivated (IGBT opened) and no power
is present on the motor's output. The power stage relay
must
then be powered (pin 4 to 0 V and pin 5 to
+24 VDC) to have power on the motor's output (otherwise an ’Inrush error’ will appear).
•
The
motor's
short-circuit relay
(+ 24 VDC / 490
Ω
), which is
optional
, allows the user to short-circuit the
motor's phases.
If this relay is not powered, the motor's phases are shorted. The motor's short-circuit relay
must
then be
powered (pin 1 to +24 VDC) to have power on the motor's output.
Phoenix Contact PC 4/3-G-7.62 (plastic connector)
P
OWER
I
NPUT
Signal
Function
3-phase
mains
1-phase
mains
L1
Mains input for power supply (84 to 280 VAC MAX, between L1-L2)
Mains L1
Mains L1
L2
Mains input for power supply (84 to 280 VAC MAX, between L2-L3)
Mains L2
Mains L2
L3
Mains input for power supply (84 to 280 VAC MAX, between L3-L1)
Mains L3
Do not
connect
Phoenix Contact MC 1.5/5-STF-3.81
(plastic connector)
A
UXILIARY
INPUT
Pin #
Signal
Function
1
Optional short-circuit relay
Motor's short-circuit relay supply input (24 VDC (referred towards GNDaux))
2
GNDaux
Auxiliary supply input (0 V)
3
Vaux
Auxiliary supply input (24 VDC)
4
Power stage relay -
Relay supply input (0 V)
5
Power stage relay +
Relay supply input (24 VDC)
POWER INPUT
JC13
L1
L2
L3
AUX.
1 2 3 4 5
JC12
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com