![ETC transtechnik FDX2000 Operating Manual Download Page 28](http://html1.mh-extra.com/html/etc/transtechnik-fdx2000/transtechnik-fdx2000_operating-manual_2431362028.webp)
Appendix
Improvements and New functions
Since versions 1.12.1 and 1.18.1 the following improvements and new functions were built into the
software:
•
Timing on DMX-inputs. If breaks within a DMX telegram exceeded a certain limit, the following
channels were misinterpreted. This was visible in uncontrolled flickering of lamps. Especially
consoles of type Avab Presto faced this problem.
•
The performance of the network module has considerably been improved, so that there is no loss
of data packets at high network load and visible steps on dimmer output could be eliminated
•
Measurement of input voltage is extended to 285 V.
•
Not all settings were handled on saving or restoring of the configuration using either a console or
PC-software WinDFB. Now all settings are saved and restored.
•
On very short loss of power dimmer fade in according to the follow-up times is disabled. This
avoids flicker.
•
Priorities for AVAB/UDP protocol added
•
New dimmer curves VIP90 and ANDI added
•
16 bit control on inputs added
•
Dimmer protocol sACN added
•
Status LEDs have been updated and improved
•
Display of dimmer control values
•
Presets can be controlled by external signals
•
DMX patch per dimmer
– 24 –
FDX2000 Vers. 4.0.0