16
Irideon WLZ User Manual
Portable Fixture DMX Pinout
Pin
Wire Color
Description
1
White/Orange
DMX1 +
2
Orange
DMX1 -
3
White/Green
DMX2 +
4
Blue
Not Connected
5
White/Blue
Not Connected
6
Green
DMX2 -
7
White/Brown
Iso Common
8
Brown
Iso Common 2
Configuration
Set the DMX Address at the Fixture
You can set the DMX address using RDM, but you can also set the DMX
address on the fixture itself, if necessary. The fixture uses the last address
that you set, regardless of whether you set it via RDM or locally on the
fixture.
There are three addressing dials on the track adapter (track-mounted
fixture), in the canopy (canopy fixture), or on the driver box (portable
fixture). To set the DMX address, use a small flatblade screwdriver to
move the arrow to the desired address number.
DMX addresses must be set between 1 and 512. Each fixture must be
considered a separate DMX device for the purpose of DMX line-loading
calculations. The Irideon WLZ only has an intensity channel.
Note:
When using RDM with track-mounted fixtures, ETC
recommends connecting no more than 20 fixtures on a single run.