6
Irideon WLZ User Manual
Connect Canopy Wiring (DMX Variant)
Cable preparation instructions for DMX termination are included in the
termination kits, and are also available for download at
.
1. Remove the adhesive tape or fasteners securing the mounting plate
to the fixture to free the mounting plate from the canopy
enclosure.
WARNING:
RISK OF ELECTRIC SHOCK! Install the cover plate
as directed below for installations where the interior of the
canopy enclosure could be exposed after installation with only
the mounting plate. For example, install the cover plate when
installing to a surface-mount back box.
AVERTISSEMENT :
Installez la plaque de protection comme
indiqué ci-dessous pour les installations où l'intérieur de la
rosace de plafond pourrait être exposé après l'installation
avec uniquement la plaque de montage. Par exemple, installez
la plaque de protection lors de l'installation sur un boîtier
arrière à montage en surface.
2. Are you flush-mounting the fixture or surface-mounting the
fixture?
•
Flush-mounting: Continue to step 3.
•
Cover plate (if needed
for surface-mounting)
Mounting plate
Surface-mounting:
Position the cover plate
on top of the mounting
plate before wiring the
fixture. The cover plate is
required when the interior of the canopy enclosure could be
exposed after installation with only the mounting plate (the
mounting surface is smaller than the canopy enclosure).
3. Terminate DMX/RDM input from the control source to the back
box.