Irideon WLZ User Manual
9
1
1
2
2
Mounting plate
(DMX variant)
Canopy
bolt hole
For this
structure...
...secure mounting
plate using:
4-11/16 in
back box
Large oval slots
(see 1 at left)
4 in back box
Small oval slots
(see 2 at left)
2.
Hook
Use the hook in the canopy enclosure to
hang the fixture from the mounting plate
while you complete the fixture wiring.
3. If desired, manually set the DMX address
on the fixture using the three addressing
dials in the canopy. See
Address at the Fixture on page 16
4. Connect the pre-wired DMX connector on the fixture to the mated
connector on the mounting plate (shown below).
5. Terminate DMX/RDM data signal for the last DMX/RDM device in
the data run by setting the termination switch to ON (to the right,
as shown below). All other devices in the data run should retain
the default setting for the termination switch (OFF).
6. Following the label on the mounting plate, attach the power wires
to the power block.
ON
Mounting plate
DMX connector
Termination switch
Power block