appendix a installation
313
RVI ETCNet DIP switch settings
In order to enable the Remote Video Interface (RVI) for use on the ETCNet
network, you must first adjust the settings of the two sets of ETCNet DIP
switches. You will need to use a pin, or a similar fine-pointed object, to set
the switches.
To set the switches, follow these steps.
1.
Locate the two sets of DIP switches, visible through the right side
panel of the RVI.
2.
If the ETCNet cable is plugged into the BNC (ThinNet) connector, set
the back six DIP switches to
Off
(up). Set the front six to
On
(down).
3.
If the ETCNet cable is plugged into the RJ45 (Twisted Pair) connector
or the DB15 (ThickNet) connector, set the front six switches to
Off
(up). Set the back six to
On
(down).
1 2 3 4 5 6 1 2 3 4 5 6