Operation
63
Test
Test is used to test the fixture and display its output values. Test overrides all other control to the
fixture. The action options are All Off, All On, Chase, and Ind Cntl (Individual control). The default is All
Off.
To exit the Test screen, press [
] twice. The fixture will revert to its previous state.
1:
On the Diagnostics screen, scroll to Test.
2:
Press [
].
Figure-4.34 Test Screen in Chase mode
3:
With Action selected, press [
] to toggle between the options.
4:
Press [
] or [
] to commit the option.
C h a s e
Chase automatically sequences through each LED color and starts each at 0% intensity and steps up to
100% before moving to the next color. You can set the number of steps per second for sequencing
through all LED colors individually.
1:
On the Test screen, scroll to Action.
2:
Press [
] until the Chase option displays.
The fixture begins to sequence through the LEDs.
3:
Press [
] to select Chase.
4:
Press [[
] to select the values.
5:
Press [
] or [
] to set the number of steps per second.
The range is 10 to 20.
6:
Press [
] to commit the value.
The percent of intensity is displayed for each color as the fixture sequences through them.
7:
To stop the test, do one of the following:
• Press [
] or [
] to select Action and then press [
] until All Off displays.
• Press [
] to return to Action and then press [
] until All Off displays.
Diagnostics
Individual Control
Test
Action
: Chase
Chase: 15
steps/sec
G O R A O R I
00 00 48 00 00 00 00
Brightness
LED series