ETC
Quick reference
DMX control channels
*Use DMX values of 0 or 255 for no strobe. Use values of 1–254 to increase
the strobe rate from 1 per second up to 33 per second.
Error codes
There are three error codes that may be shown on the user interface.
•
: Screen toggles between
and
to indicate a problem
with the color calibration. The fixture will need to be returned to the
ETC factory; contact your local dealer to set up a repair.
•
: Screen toggles between
and
to indicate that the
fixture has gone into over-temperature protection mode to avoid
damaging the fixture. Once the fixture has self-cooled, the error will
automatically clear.
•
: Screen toggles between
and
to indicate that the
upgraded fixtures have a software issue. Reload software to clear the
error. If the error persists, contact ETC.
DMX
Channel
(Variable
Color Temperature)
(Direct)
(1 Channel)
1
Intensity
Intensity
Intensity
2
Color temperature
Warm white
3
Cool white
4
Strobe*