background image

ETC Installation Guide

ColorSource CYC v1.7/v3.1

Electrical

Operates between 100 V and 240 VAC at a frequency of 50/60 Hz.

Maximum power consumption is 160 W.

Up to 9 luminaires (15 A max) may be linked via power thru
connector (10 luminaires total per circuit) when used with an
R20 Relay Module or Unison Echo Relay Panel. Consult breaker trip
curves when used with other equipment. Requires power from a
non-dimmable source.

Inrush:

-

120 V: 39 A (first half-cycle)

-

240 V: 74 A (first half-cycle)

Typical Power Consumption

100 V

120 V

230 V

Power

Current

Power

Current

Power

Current

Idle

1.66 W

0.04 A

1.38 W

0.04 A

1.18 W

0.05 A

Direct at Full

133.7 W

1.34 A

132.6 W

1.11 A

130.4 W

0.59 A

RDM Values

Parameter

Value

Description

Manufacturer ID

0x6574

Electronic Theatre Controls

Model ID

0x0215

ColorSource CYC (v1.7) or
ColorSource CYC CPU2 (v3.1)

DMX Start Address

0x00F0

Range = 1–512

DMX Personality

0x00E0

1 = 5 Channel
2 = Direct
3 = 1 Channel
4 = RGB

Output Frequency

0x8123

0 = Standard (1.2 kHz)
1 = High (25 kHz)

ColorSource CYC

Page 11 of 12

ETC

Summary of Contents for ColorSource CYC

Page 1: ...nic Theatre Controls Inc Trademark and patent info etcconnect com ip Product information and specifications subject to change ETC intends this document to be provided in its entirety 7415M2100 1 7 Rev...

Page 2: ...taller le projecteur sur ou c t d une surface inflammable D branchez le projecteur de son alimentation et du DMX et laissez le refroidir avant d installer des accessoires ou d effectuer un nettoyage o...

Page 3: ...les d chets m nagers mais doit tre d pos dans une collecte de d chets lectroniques ou dans un point de collecte Protective earth ground Protection Classe I Mise la terre Safety cable anchor point Yoke...

Page 4: ...ure 1 Plug the power cord into the powerCON In connector on the rear of the fixture 2 Make any power thru cable connections prior to applying a power source 3 Make any DMX connections and if the fixtu...

Page 5: ...hange the DMX Control Mode You can set the DMX control mode for the fixture to one of four available mode options 1 Press any button to wake the display The display shows the DMX address 2 Press and h...

Page 6: ...e 4 Blue Blue 5 Strobe Indigo 6 Lime 7 Strobe Use DMX values of 0 or 255 for no strobe Use values of 1 254 to increase the strobe rate from 1 per second up to 33 per second Data Loss Behavior When DMX...

Page 7: ...te the Presets Sequences menu The last active preset or sequence plays automatically If DMX data is present the current preset or sequence plays in the background and DMX data continues to take priori...

Page 8: ...B mode rgb the intensity is set to full and the strobe is turned off See Change the DMX Control Mode on page 5 Adjust the Intensity of Presets 1 Ensure that DMX data is not present 2 Press the Mode bu...

Page 9: ...l ignore any other fixture types in the DMX run Note Not sure what version of fixture software is installed The version number appears on the display when the fixture powers up This fixture can push s...

Page 10: ...lear If the error does not clear contact ETC Technical Support visit etcconnect com contactETC No App Screen toggles between no and APP to indicate that the upgraded fixtures have a software issue Rel...

Page 11: ...e source Inrush 120 V 39 A first half cycle 240 V 74 A first half cycle Typical Power Consumption 100 V 120 V 230 V Power Current Power Current Power Current Idle 1 66 W 0 04 A 1 38 W 0 04 A 1 18 W 0...

Page 12: ...and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the...

Reviews: