ETAS
Technical Data
ES600.2 - User Guide
35
7.10
Electrical data
7.10.1
Voltage supply
7.10.2
"GE-HOST" connection
7.10.3
"FE-HOST" connection
Operating voltage
7 V to 29 V DC
Current consumption, operation
1)
Typ. 210 mA at 14.4 V DC
Current consumption, standby
1)
Typ. 60 mA at 14.4 V DC
Current consumption, maximum
14 A
Power supply of connected mod
-
ules
Each "ETH" connection: nom. max. 2 A
Energy management
On/Off with Start/Stop of Ethernet data
transfer (On/Off upstream module)
Protection
Reverse polarity-protected and load
dump protection in accordance with ISO
16750-2 Test B (central load dump pro
-
tection required)
Overvoltage category (AC mains
supply)
II
1)
: without power supply of connected modules
Connection type
Upstream
Number
1 (GE-HOST)
Connection
10Base-T/100Base-TX/1000Base-T
Ethernet
Synchronization
IEEE1588-2008 synchronization
Compatibility
1)
PC
ES8xx modules
1)
: Support of ES800 modules functionality "Wake-Up" / "Sleep"
NOTE
For the successful initialization of the network card of your PC, observe chap
-
Connection type
Upstream
Number
1 (FE-HOST)
Connection
10Base-T/100Base-TX Ethernet
Synchronization
ETAS synchronization mechanism
IEEE1588-2008:
no synchronization, no forwarding of
synchronization signals