The ES600.2 and modules connected to it automatically switch to the
"Standby" operating state if no connection receives any link signals any longer
or the host computer is switched off or disconnected. As soon as at least one
of these connections receives link signals or the host computer is activated
again, the module automatically changes to the "On" operating state ("Wake-
Up" function) and automatically switches on all ETAS modules connected in the
measuring system.
5.6
Firmware update
The firmware of the ES600.2 can be updated by the user so that future versions
of the module can also be used. The firmware update is done with the help of
the service software "Hardware Service Pack" (HSP) from the connected PC.
NOTE
The automatic switch-on of the ES600.2 via the "Wake-Up" function is possi
-
ble at all Ethernet connections.
NOTE
For a connected PC to send link pulses, its Ethernet adapter must be config
-
ured accordingly.
NOTE
During a firmware update, neither the voltage supply nor the Ethernet connec
-
tion may be interrupted!