ETAS
Technical Data
ES600.2 - User Guide
31
7.1.2
Standards met
The module meets the following standards:
7.1.3
Ambient conditions
7.1.4
Maintenance of the product
Do not open or change the module housing! Work on the module housing may
be performed only by qualified technical personnel. Return defective modules
to ETAS for repair.
7.1.5
Cleaning the product
We recommend cleaning the product with a dry cloth.
7.1.6
Mechanical data
Standard
Test
EN 61326-1
Electrical equipment for measure
-
ment, control and laboratory use -
EMC requirements
EN 61000-6-2
Immunity for industrial environments
EN 61000-6-3
Interference emissions (living area,
business and commercial areas as
well as small enterprises)
EN 60 529
Degree of protection through housing
(IP code)
EN 60 068-2-31
Fundamental environmental testing -
Part 2: Tests; Test ed: free falling
Operating temperature range
-40 °C to +70 °C
-40 °F to +158 °F
Storage temperature range
(module without packaging)
-40 °C to +85 °C
-40 °F to +185 °F
Relative humidity (non-condensing) 0 to 85% (operation)
0 to 95% (storage)
Operating altitude
max. 5,000 m / 16,400 ft
Degree of protection
IP40
Contamination level
2 (acc. to IEC 60664-1 and IEC 61010-1)
NOTE
The module is suitable for use in interiors, in the passenger cell or in the trunk
of vehicles. The module is
not
suitable for installation in the engine compart
-
ment and similar environments.
Dimensions (H x W x D)
36 mm x 127 mm x 160 mm
1.42 in x 5.0 in x 6.3 in
Weight
approx. 0.64 kg / 1.42 lb