Commissioning
ES600.2 - User Guide
24
Fig. 6
-
2
Blind hole with thread
6.1.3
Mechanically connecting several modules
Because of the use of ETAS system housings, the Synchronization and Power
Management Module can also be connected with modules of the ETAS com
-
pact series (ES59x, ES6xx, ES910). They can easily be combined into larger
blocks using the supplied T-connectors.
Underneath the ES600.2, you can attach an additional module of the ETAS
compact series. To do so, remove the four plastic feet each at the correspond
-
ing side of the device and install the supplied T-connectors in their place.
Mechanically connecting several modules:
1. Remove the four plastic feet at the underside of the ES600.2 to
be able to fasten an additional module.
This exposes the installation openings for the T
-
connectors.
You can attach an additional module underneath the ES600.2.
2. Remove the four plastic feet on the corresponding side of the
second module.
3. Turn the locks of the T-connectors crosswise to the longitudi
-
nal axis of the connectors
4. Click two connectors into the installation openings at one lon
-
gitudinal side of the first module.
5. Click the second module into the two T-connectors.
CAUTION
Possible damage or destruction of electronics!
Do not process the existing tapped hole.
NOTE
Screw the module onto your carrier system using
exclusively
M3 cylinder
screws and a max. torque of 0.8 Nm.
The screw-in depth in the blind hole of the housing measures max. 3 mm (see
Fig. 6
jP
MKOR=ñ=QRø
PKR=
ãá
å
QKR=
ã~
ñ