ES5321.1 PWM I/O Board (48/32-CH) - User’s Guide
37
ETAS
Technical Data and Norms
Power Supply
Storage Conditions
Ambient Conditions
Physical Dimensions
5.2
Fulfilled Norms and Standards
The ES5321.1 meets the following norms and standards:
The module is only intended for use in industrial settings in accordance with
EN 61326-1. Avoid potential radio interference when using the module outside
of the industrial settings with additional shielding measures!
Current consumption
250 mA @ +3.3 V DC
1 A @ +12 V DC
Temperature
-20 °C to 85 °C (-4 °F to 185 °F)
Relative humidity
0 to 95% (non-condensing)
Environment
Use only inside enclosed and dry rooms
Max. contamination level
2
Temperature during operation
5 °C to 40 °C (41 °F to 104 °F)
Relative humidity
0 to 95% (non-condensing)
Operating altitude
-200 m to 2000 m/ 6500 ft above sea level
Height
4 U
Relative humidity
5 HP
Weight
0,5 kg
Standard
Test
IEC 61326-1
Electrical equipment for measurement, control and laboratory
use – EMC requirements (industrial setting)
IEC 61010-1
Safety requirements for electrical equipment for measurement,
control and laboratory use - Part 1: General requirements
WARNING!
This is class A equipment. This equipment can cause radio interfer-
ence in residential areas. In this case, the operator may be required to
institute reasonable measures.
Summary of Contents for ES5321.1
Page 1: ...ES5321 1 PWM I O Board 48 32 CH User s Guide...
Page 18: ...ES5321 1 PWM I O Board 48 32 CH User s Guide 18 Introduction ETAS...
Page 34: ...ES5321 1 PWM I O Board 48 32 CH User s Guide 34 Connections and Connectors ETAS...
Page 40: ...ES5321 1 PWM I O Board 48 32 CH User s Guide 40 ETAS Contact Addresses ETAS...