ES5321.1 PWM I/O Board (48/32-CH) - User’s Guide
26
In- and Output-Signals
ETAS
3.1.1
Configuration with ES5436.1 to Measure ECU Digital Output Signals
Digital outputs of ECUs are often configured as open emitter or open collector.
In a vehicle, such outputs are connected to small loads.
To measure such digital output signals of an ECU in a HiL setup, the ES5436.1
can be used as load simulation and the ES5321 for measurement.
A schematic diagram for the ECU, the ES5321.1 and the ES5436.1 is shown in
Fig. 3-1 on page 27.
The ES5436.1 has 48 current channels for currents in the range of 5 mA to 150
mA. These current channels can be combined with the 48 digital inputs of the
ES5321.1 or the ES5321.2.
Technical Data of the ES5436.1 Power Sources
Tab. 3-1
Technical data of the power sources
When connecting the ES5436.1, observe the following note:
CAUTION!
Before connecting the ES5436.1, read the ES5436.1 User’s Guide.
Output
Data
Output current
5 mA to 150 mA
Output voltage
Passive circuit
Accuracy
+/- 3 mA at 150 mA
Galvanic isolation
max. 60 V to ground potential (functional separa-
tion)
Overvoltage protection
60 V abs. max.
Note
In the idle state (non activated load channel, operation mode "disabled") the
power source’s idle state current is ~70
μ
A.
Note
If the external vVBAT < 6 V the power source doesn’t carry any current.
Note
The ES5436.1 use cases "Pull-Up“, "Pull-Down“ and "Bipolar“ ( "Bipolar" for H-
bridge configuration, see ES5436.1 User’s Guide) can be configured by soft-
ware.
For this reason, make sure that +VBAT and -VBAT are always connected.
Summary of Contents for ES5321.1
Page 1: ...ES5321 1 PWM I O Board 48 32 CH User s Guide...
Page 18: ...ES5321 1 PWM I O Board 48 32 CH User s Guide 18 Introduction ETAS...
Page 34: ...ES5321 1 PWM I O Board 48 32 CH User s Guide 34 Connections and Connectors ETAS...
Page 40: ...ES5321 1 PWM I O Board 48 32 CH User s Guide 40 ETAS Contact Addresses ETAS...