ETAtouch controller
[External heat source] function block
65
5.8.1
Text menu - Adjustable parameters
Adjustable parameters
Detailed descriptions of the parameters are provided
below.
5.8.1.1
Switch off boiler at
Explanation of [Switch off boiler at]
This parameter determines at what temperature of the
external heat source the ETA boiler switches to
[Locked] mode.
If the temperature of the external heat source lies
below this temperature [Switch off boiler at], the ETA
boiler always supplies the heat. If this temperature is
exceeded, the ETA boiler switches to [Locked] mode.
The parameter can be found under:
5.8.1.2
Enable diverter valve
Explanation of [Enable diverter valve]
Optional: Only with diverter valve
This parameter is used to set the minimum
temperature for the switchover between the ETA boiler
and the external heat source.
If the temperature of the external heat source is below
this minimum temperature, the diverter valve switches
to the ETA boiler, which then supplies the heat. If this
temperature is exceeded, the valve switches to the
external heat source, which supplies the heat.
The parameter can be found under:
5.8.1.3
Enable temperature
Explanation of [Enable temperature]
Optional: only with charging pump
This parameter sets the minimum temperature of the
external heat source, for starting the charging pump of
the external heat source.
The parameter can be found under:
5.8.1.4
Thermostat diff.
Explanation of [Thermostat diff.]
Optional: only with charging pump
This parameter is used to set the minimum difference
between the temperature of the external heat source
[Ext. heat] and the tank that needs charging [Tank tem-
perature], to start the charging pump of the external
heat source.
The parameter can be found under:
Ext. heat
Switch off boiler at
Enable diverter valve
Charging pump
Enable temperature
Thermostat diff.
Ext. heat
Switch off boiler at
Ext. heat
Enable diverter valve
Charging pump
Enable temperature
Charging pump
Thermostat diff.
Summary of Contents for PelletsCompact 20-32 kW
Page 1: ...2017 04 19 EN 0000000282 V 003 3 38 1 1910 93108 002 PelletsCompact 20 32 kW Operation...
Page 27: ...ETAtouch controller Getting to know the control system 27...
Page 31: ...ETAtouch controller Boiler function block PelletsCompact 20 32 kW 31...
Page 41: ...ETAtouch controller Buffer function block 41...
Page 45: ...ETAtouch controller Hot water tank function block 45...
Page 49: ...ETAtouch controller Fresh water module function block 49...
Page 63: ...ETAtouch controller Solar function block 63...
Page 67: ...ETAtouch controller Pellet store function block 67...
Page 74: ...www eta co at...
Page 75: ......
Page 76: ...www eta co at www eta co at downloads DOWNLOAD...