Troubleshooting
The LED "Operation" or "Fill-
ing" in the connection box
flashes in a cycle 2x
The sensor for the filling position of
the mole in the lifting module is defec-
tive
Free the mole from the spill. Restart the lift
module with a power interruption of at least
5 seconds.
If the error occurs again, the lifting module
must be replaced.
The cable in the lifting module is bro-
ken
Replace the cable reel and cable.
The "Operation" or "Filling"
LED in the connection box
flashes in a cycle 3x
The speed sensor in the lift module is
defective
Free the mole from the spill. Restart the lift
module with a power interruption of at least
5 seconds.
If the error occurs again, the lifting module
must be replaced.
The mole is buried
Free the mole from the spill. Restart the lift
module with a power interruption of at least
5 seconds.
Fault
Cause
Solution