Cleaning and maintenance
Regular maintenance
9
Actuate the locking lever so the bottom folds out. Do
not let the bottom strike anything or become bent, so
that the seal on the bottom fits evenly.
Fig. 2-3: Actuating the locking lever
After emptying, clean the bottom seal and sealing
surface in the boiler. Inspect the seal to ensure it is in
good order; replace it if necessary.
Fig. 2-4: Seal and sealing surface in the boiler
Then fasten the floor of the ash bin again with the
locking lever. Make sure the lever engages properly.
Unhook the connection unit, place it onto the ash bin
and lock it with the screw cap.
Fig. 2-5: Screw cap
Check the function
of
the
posi-
tion switch for the ash bin. The switch must be
actuated when locking the screw cap.
Fig. 2-6: Position switch